Check Interferences From the Rebar Interference Command
- From the Reinforcement section of the action bar, click Rebar Interference .
-
Select a rebar layer.
Alternatively, you can select the containing part: in this case, all the rebar layers of the part are selected. If the part contains rebar layers in No/Show mode, you can account them or ignore them in the calculation.
-
Select the interference computation mode
- Between components: To compute interference between rebar layers.
- Inside component : To compute interferences inside a rebar layer.
You can select both modes.
- Optional:
Select the second set that can be the concrete part (surface or solid) or another
rebar.
Whether you need to select the second set depends on the first set configuration and can be optional.
- If the first set contains at least one rebar layer and the option to compute interference inside rebar layers is selected.
- If the first set contains at least two rebar layers and the option to compute interference between rebar layers is selected
Note: The elements of the first set cannot be selected in the second set. -
Select the Automatically add new bars to this set check box
If a rebar layer is created later than the interference feature, this rebar layer will be automatically added to the interference computation.Note: Although this option is available for both sets, its usage is exclusive. If you selected it for the first set, then it is not available for the second set and conversely.
-
Adjust the interference parameters. By default, only the clash and contact issues are
detected. Select a specific parameter or combine several parameters:
- Cover Thickness: Is the clearance value for other elements. This value can be negative, in this case it is considered as a penetration depth (can be time consuming).
- Rebar Clearance: Is the clearance for rebar layers.
- Minimum diameter : Use it to ignore small bars during the computation.
-
Select a computation mode.
By default, the Raise only a warning check box is selected.