From the Validation section of the Flow optimization
assistant panel, select Setup Validation.
-
Optional: From the Setup validation panel,
click Configure to configure the fluid set mesh.
- From the Mesh options dialog box, define the mesh size.
You can click Auto to reinitialize the mesh size to its default value.
A fine mesh gives a more accurate result but
increases the duration of the computation. -
Optional: In the Expert options frame, do
the following:
-
To unlink the thickness of the first boundary layer with the mesh size,
clear Link boundary layer thickness to mesh
size.
-
Define the thickness of the first boundary layer.
-
Define the number of layers.
-
Define the ratio for the layer thickness growth.
The thickness of the second boundary layer equals the thickness of the
first layer multiplied by the ratio, and so on.
-
Optional: Click Display to view information
about the quality and the element type of the meshes.
-
From the Setup validation panel, click
Verify .
 An information message appears when the
verification of both model and scenario is
completed.
|