3DHvac_Part_DefaultSpecification

This check verifies whether a user-defined specification is set on the line ID containing the part. If not, the check fails.

This page discusses:

Context

At the end of the design, the Line ID containing the part must use a dedicated specification different from the default specification.

Note: The check also fails if:
  • No specification is set on the line ID.
  • The default specification is set on the line ID.

Tip: You can also perform the 3DHvac_RigidRoute_DefaultSpecification check.

This check is used in a line ID driven design context.

Check Information

Check Details Description
Applicable to: HVAC_Part_Occurrence
Automatic Solution:
Check Parameters: None