3DHvac_RigidRoute_FabricationEndStyle

This check verifies whether the end style of the two extremities of the rigid route is valid, based on the Duct Fabrication End Style table. If not, the check fails.

This page discusses:

Context

The end style of a route determines which auto part can be placed on a route end. The Duct Fabrication End Style table lists all possible end styles for a route.

Note: The check also fails if:
  • No specification is set on the rigid route.
  • No Duct Fabrication End Style table exists in the specification.
  • The Duct Fabrication End Style table does not return any values for this context.

For more information about the table, see HVAC Design Administration Guide: Data Setup: HVAC Resource Files: Resource Files - Common Tables: Duct Fabrication End Style.

Check Information

Check Details Description
Applicable to: HVAC_Duct_Occurrence
Automatic Solution:
Check Parameters: IsToUseDefaultSpecification: Boolean type.

Specifies whether to use the default specification when no specification is set on the rigid route.

Note: By default, the value is set to TRUE.