Non_Allowed_Solid_Feature_Mixed_With_Boolean_Feature

This check verifies whether certain types of solid features and boolean features are situated inside the same body on the same specification-tree level. If so, the solid features are considered as incorrect.

This page discusses:

Context

To rearrange the incorrectly arranged components in the specification tree, do one of the following:

  • Change the sequence of the elements.
  • Move the elements to another body.

The following reference types can be specified as non-allowed:

Link type Icon Description
Internal CCP Geometry copied from the same part, synchronized
Non-associative Copied element without associativity
External Broken link (status not yet propagated to the PLM database)
External Broken link (status propagated to the PLM database)
External Geometry copied from other part, synchronized
External Not synchronized geometry

Check Information

Check Details Description
Applicable to: BodyFeature
Automatic Solution:
Check Parameters:
  • CheckBooleanBodies: Boolean type.

    Checks the bodies aggregated under boolean operation.

  • IgnoreFeaturesAfterLastBooleanOperation: Boolean type.

    Ignores the feature after the last boolean operation.

  • NonAllowedSolidFeatures: Multi Value Parameter type.

    The following values can be selected: Pad, Chamfer, AutoDraft, AutoFillet, CircPattern, CloseSurface, EdgeFillet, FaceFillet, FunctionalSolid, Groove, GSMLoft and GSMRotate.

  • NonAllowedAssociativeFeatures: Multi Value Parameter type.