Non_Allowed_Basic_Dimension_Reference

This check verifies whether one or both reference points of a framed basic dimension are situated on a constructed drill-hole axis. If not, the FTA element is displayed as incorrect.

This page discusses:

Context

In case of framed basic dimensions, this check helps to avoid the incorrect geometry references.

Check Information

Check Details Description
Applicable to: CATTPSBasicDim
Automatic Solution: No
Check Parameters: None