V5 to 3DEXPERIENCE Data Import Table
The following table describes import correspondences between V5 file-based data and 3DEXPERIENCE content.
The statuses for import results are fully imported, partially imported, and not imported (-).
| V5 Data Type | 3DEXPERIENCE Content Type | Import Effect | |
|---|---|---|---|
| Wires | |||
| Wire reference products | Conductors references | Fully imported | |
| Wire group reference products | Conductor groups references | Fully imported | |
| Devices | |||
| Electrical behavior added to reference parts | Electrical behavior added to reference parts | Fully imported | |
| Electrical behavior added to reference products, except splices (see below) | - | - Only reference parts are considered as electrical devices. V5 electrified products are imported as geometry. | |
| Splice reference product | Splice reference product | Partially imported Only the Length and Equivalence thickness attributes are imported. | |
| Electrical behavior added to part instances | - | - Only reference parts are considered as electrical devices. As a consequence:
| |
| Connection points | |||
| All connection points, except terminations | All connection points, except terminations | Fully imported | |
| Terminations | Cavities | Partially imported
| |
| Reference retainer parts | |||
| Reference support parts | Reference support parts | Fully imported Only if the supports are created or edited after V5R17. | |
| Reference retainer parts | Reference retainer parts | Fully imported | |
| Reference adapter parts | Reference adapter parts | Partially imported Reference adapter parts are imported as regular (non-adaptative) supports | |
| Protective coverings | |||
| Instantiated external protective covering | Protective covering feature in the electrical branch geometry | Fully imported The feature does not inherit the show/no show attribute of the instantiated protective covering. | |
| External protective covering product reference | External protective covering product reference | Fully imported | |
| External protective covering reference to use for instantiation | Standard 3D part | Partially imported | |
| Internal protective covering | Internal protective covering | Fully imported | |
| Regular protective covering attributes | Protective covering attributes | Fully imported | |
| Adjust relation on regular protective coverings | - | - | |
| Elec_Text attribute on Protective Coverings | Elec_Text attribute on Protective Coverings | Fully imported | |
| Instances | |||
| Instances of reference parts where electrical behavior added to reference part | Instances of reference parts where electrical behavior added to reference part | Fully imported The reference designator is replaced by instance the name. | |
| Splice instance | Splice instance | Fully imported Splice position, and link between splice and end of segment are imported.
| |
| Electrical Connections | |||
| Between devices that are geometrically connected with mechanical constraint | Between devices that are geometrically connected with mechanical constraint | Fully imported | |
| Between devices that are not geometrically connected | - | - The electrical link is lost. | |
| Publications | |||
| ElecLogTerm | - | - | |
| SegmentExtremity | - | - | |
| Logical Termination | - | - | |
| Wire Extremity | - | - | |