From the E-Cooling section of the action bar,
click TEC Component
.
- Optional:
Enter a descriptive
Name.
-
From the 3D area, select a
bounding box as the
support.
-
From the 3D area, select
the cold side of the TEC.
The cold side of the TEC is usually closest to the heat source.
-
From the 3D area, select
the hot side of the TEC.
The hot side of the TEC is usually farthest from the heat source.
-
Enter a value for the Maximum temperature difference supported,
which is the maximum temperature difference between the cold and hot sides of the TEC for
the device to be effective.
-
Enter a value for the Voltage at device current maximum, which
is the electric potential of the TEC's circuit at the maximum supported input
current.
-
Enter a value for the Maximum current for device effectiveness,
which is the maximum current at which the device remains effective.
-
Enter a value for the Geometry factor, which is the average
area-to-height ratio of the semiconductor pellets inside the TEC.
-
Enter a value for the Number of thermocouples, which is the
total number of n- and p-type semiconductor pellet pairs.
One thermocouple consists of one p-type pellet and one n-type pellet.
-
Click OK.
|