Reposition Fasteners After Modifying Stacking Parts
For the purpose of our scenario, the original stacking parts have been modified.
Select the fasteners.
In the Positioning Analysis dialog box, click Analyse
selected fasteners
.
The analysis results appear in the Results area of the
dialog box. The three fasteners are listed in Unable to compute fastener
position.
Fastener 1 and
fastener 2 cannot be projected on the original surface that has been
modified.
To edit the fasteners, in the dialog box, right-click Fastener 1 and select
Edit, and assign a new surface manually. Repeat the operation
for the second fastener.
Tip:
Click a row to highlight the corresponding fastener in the
treeor the 3D area.
Click anywhere in the 3D area to
cancel the highlight.
Click a row to highlight the corresponding fastener in the
treeor the 3D area. Click
anywhere in the 3D area to
cancel the highlight.
Click Analyse selected fasteners.
In the Results area of the dialog box, two fasteners
are now listed in Fastener position computation successful.
Click OK to validate the new positioning.
Fastener 1 and Fastener 3 are repositioned successfully on the new surface.
Note:
For
fastener 2, no surface for projection can be found. You can delete it.
Reposition Flexible Fasteners After Modifying Point Location
From the Fastener section of the action bar,
click Positioning Analysis
.
In the Analysis Mode area of the dialog box, select
Manage position and thickness.
Select Analyse selected fasteners
.
To access details about the fasteners, expand the lists in the
Results area of the dialog box:
Three fasteners are listed in Fasteners in correct
position. All the fasteners in this category are shown in a white
preview. They do not need any repositioning.
Three fasteners are listed in Fastener position computation
successful. All the fasteners in this category are shown in a green
preview. This group represents the fasteners for which the point as well as the
support surfaces are successfully found. You can reposition them.
Two fasteners are listed in Unable to compute fastener
position. All the fasteners in this category are shown in a red
preview. This group represents the fasteners for which the app
cannot compute a correct position.
Click OK.
The thickness of fasteners 4, 5 and 6 is different from the newly computed
stacking thickness, but it is within range of the flexible fastener, so the corrective
action is possible. These fasteners are repositioned successfully. Conversely, the newly
computed thickness for fasteners 7 and 8 is out of range of the flexible fastener. A
corrective action is impossible. Only the position of these fasteners is modified.