Electrical Manufacturing Preparation Parameters

Electrical parameters specify how electrical components should be projected in a Drafting view.

Electrical parameters can be customized in the Standard Definition dialog box which appears when you select Me > Preferences > Standards. After selecting the generativeparameters category, you can then select the .xml file you want to customize. Electrical parameters are located in the Electrical node of this .xml file.

The parameters under Electrical are for use with electrical products only.

This page discusses:

Segment

Parameter Value Description
Representation Type DoubleLine/SingleLine Determines the line type used for Segments.

By default, , the value is DoubleLine.

LineType Integer Determines the line type.

By default, the value is 1.

LineThicknessIntegerDetermines the line thickness you want to apply.

By default, , the value is 1.

Text GenerationYes/No Specifies whether or not to generate an associated text template.
CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
SupportSectionCatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
NumberingYes/NoSpecifies whether or not to generate the numbering.
JunctionSectionCatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
NumberingYes/NoSpecifies whether or not to generate the numbering.
JunctionSymbolGenerationYes/NoSpecifies whether or not to display a symbol on harness junctions.
CatalogNameStringSpecifies the name of the catalog and chapter containing the default symbol.

By default, the catalog name is unset.

You can use the catalog provided by default: Default_Symbol_TT_Catalog.3dxml. The name of the related chapter is JunctionSymbolChapter.

Otherwise, you can select another catalog provided that it is loaded in Data Setup.

SymbolNameStringSpecifies the name of the symbol.

By default, the name of the symbol is unset.

You can use the symbol provided in the default catalog and named: JunctionSymbol.

CuttingSymbolGenerationYes/NoSpecifies whether or not to display the symbol.
CatalogNameStringSpecifies the name of the catalog containing the symbol.
SymbolNameStringSpecifies the name of the symbol.

Protection

Parameter Value Description
Adaptative > Representation Type DoubleLine/SingleLine Determines the linetype used for protective covering.

By default, the value is SingleLine.

LineThickness Yes/No Determines the line thickness used for protective covering.
ThicknessValue IntegerDetermines the line thickness you want to apply.

By default, the value is 1.

Adaptative > Filling Generation Yes/NoSpecifies whether or not to automatically fill with color the inner area of some identified protections.

By default, the value is No.

Keyword StringSpecifies the keyword that identifies the protections to be filled.

This keyword has to be added to the External Reference attribute in the properties of the protections.

Note: This attribute may also contain the keyword for the 2D details generation. To be both taken into account, keywords have to be separated by a semicolon.
Adaptive > 2DdetailOnExtremitiesGenerationYes/NoSpecifies whether or not to automatically generate the 2D Detail on protective covering end.

By default, the value is No.

CoefficientIntegerSpecifies a coefficient that sizes the 2D detail according to the layer of protective covering.

By default, the value is 1,1.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D detail (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
Adaptive > Information Table > TextGenerationYes/NoSpecifies whether or not to automatically generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
LeaderPositionProtectionCenter/ProtectionEndSpecifies the relative position the leader for an information table.
Adaptive > Information Table > SymbolGenerationYes/NoSpecifies whether or not to automatically generate the 2D Detail on protective covering end.

By default, the value is No.

PositionInInformationTableTop/BottomSpecifies the position of the adaptive diameter symbol of the protection in the information table.
CatalogNameStringSpecifies the names of the catalog or chapter in which symbol is defined. (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.

The symbol name is searched based on attribute value of reference part number or the external reference value for protection end symbols.

FixedDiameter > RepresentationTypeDoubleLine/SingleLine Determines the linetype used for protective covering.

By default, the value is SingleLine.

LineThickness Yes/No Determines the line thickness you want to apply.

By default, the value is 1.

ThicknessValueIntegerDetermines the line thickness.
FixedDiameter > FillingGenerationYes/NoSpecifies whether or not to automatically fill with color the inner area of some identified protections.

By default, the value is No.

KeywordStringSpecifies the keyword that identifies the protections to be filled.

This keyword has to be added to the External Reference attribute in the properties of the protections.

Note: This attribute may also contain the keyword for the 2D details generation. To be both taken into account, keywords have to be separated by a semicolon.
FixedDiameter > 2DdetailOnExtremitiesGenerationYes/NoSpecifies whether or not to automatically generate the 2D Detail on protective covering end.

By default, the value is No.

CoefficientIntegerSpecifies a coefficient that sizes the 2D detail according to the layer of protective covering.

By default, the value is 1,1.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
FixedDiameter > Information Table > TextGenerationYes/NoSpecifies whether or not to generate an associated text template.
CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
LeaderPositionProtectionCenter/ProtectionEndSpecifies the relative position the leader for an information table.
FixedDiameter > Information Table > SymbolGenerationYes/NoSpecifies whether or not to generate the 2D Detail.
PositionInInformationTableTop/BottomSpecifies the position of the fixed diameter symbol of the protection in the information table.
CatalogNameStringSpecifies the names of the catalog or chapter in which the symbol is defined (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
Tape > RepresentationTypeDoubleLine/SingleLine Determines the linetype used for protective covering.

By default, the value is DoubleLine.

LineThicknessYes/NoDetermines the line thickness you want to apply.

By default, the value is 1.

ThicknessValueIntegerDetermines the line thickness used for protective covering.
Tape > FillingGenerationYes/NoSpecifies whether or not to automatically fill with color the inner area of some identified protections.

By default, the value is No.

KeywordStringSpecifies the keyword that identifies the protections to be filled.

This keyword has to be added to the External Reference attribute in the properties of the protections.

Note: This attribute may also contain the keyword for the 2D details generation. To be both taken into account, keywords have to be separated by a semicolon.
Tape > 2DdetailExtremitiesGenerationYes/NoSpecifies whether or not to automatically generate the 2D Detail on protective covering end.

By default, the value is No.

CoefficientIntegerSpecifies a coefficient that sizes the 2D detail according to the layer of protective covering.

By default, the value is 1,1.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
Tape > Information Table > TextGenerationYes/NoSpecifies whether or not to automatically generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
LeaderPositionProtectionCenter/ProtectionEndSpecifies the relative position the leader for an information table.
Tape > Information Table > SymbolGenerationYes/NoSpecifies whether or not to generate 2D details.
PositionInInformationTableTop/BottomSpecifies the position tape symbol in the information table.
CatalogNameStringSpecifies the names of the catalog or chapter containing symbol (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.

By default, the name is Catalog_Symbols.

CorrugatedTube > RepresentationType DoubleLine/SingleLine Determines the linetype used for protective covering.

By default, the value is DoubleLine.

LineThicknessYes/NoDetermines the line thickness you want to apply.

By default, the value is 1.

ThicknessValueIntegerDetermines the line thickness used for protective covering.
CorrugatedTube > FillingGenerationYes/NoSpecifies whether or not to automatically fill with color the inner area of some identified protections.

By default, the value is No.

KeywordStringSpecifies the keyword that identifies the protections to be filled.

This keyword has to be added to the External Reference attribute in the properties of the protections.

Note: This attribute may also contain the keyword for the 2D details generation. To be both taken into account, keywords have to be separated by a semicolon.
CorrugatedTube > 2DdetailOnExtremitiesGenerationYes/NoSpecifies whether or not to automatically generate the 2D Detail on protective covering end.

By default, the value is No.

CoefficientIntegerSpecifies a coefficient that sizes the 2D detail according to the layer of protective covering.

By default, the value is 1,1.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
CorrugatedTube > Information Table > TextGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
LeaderPositionProtectionCenter/ProtectionEndSpecifies the relative position the leader for an information table.
CorrugatedTube > Information Table > SymbolGenerationYes/NoSpecifies whether or not to generate an associated symbol.
PositionInInformationTableTop/BottomSpecifies the position of the corrugated tune symbol in the information table.
CatalogNameStringSpecifies the names of the catalog or chapter containing symbols (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
3DOrientationAngleGenerationYes/NoSpecifies whether or not to automatically generate the information of the protective covering orientation.

By default, the value is No.

Note: Parameters are the same for all protective coverings.

Device

ParameterValue Description
SingleInsertConnector > Representation Type 3Dprojection/2D detail Specifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientation Yes/No Specifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.
CatalogName StringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
SingleInsertConnector > InformationTable > PropertiesRelativePositionToRepresentationIntegerSpecifies the relative position of information table with respect to the representation.
VerticalCellMarginIntegerSpecifies the vertical distance between two items.
HorizontalCellMarginIntegerSpecifies the horizontal distance between two items.
SingleInsertConnector > InformationTable > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
SingleInsertConnector > InformationTable > FooterGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
SingleInsertConnector > InformationTable > ConnectorTable > PropertiesGenerationYes/NoSpecifies whether or not to generate an associated text template.
GenerateHeaderYes/NoSpecifies whether or not to generate an associated text template.
TableSplitIntegerSpecifies the number of lines in a table split.
SpaceBetweenTwoSplitIntegerSpecifies the space separating two splits of the table.
SplitOptionHorizontal/VerticalSpecifies if a table split is horizontal or vertical.
CellMarginIntegerSpecifies the margins value in a table cell.
DisplayUnitYes/NoSpecifies whether or not to generate an associated text template.
SortingAscending/DescendingSpecifies the sorting order.

Priority is always given to numbers. For alphanumeric initial, sorting is performed in alphabetical order and then in numeric order.

Important: The sorting is not case-sensitive.
DisplayEmptyCavityYes/NoSpecifies whether or not to display empty cavities in the table. When the parameters is set to Yes, a dash (-) appears in the corresponding cells.
MergeDuplicateCavityYes/NoSpecifies whether or not to merge cells corresponding to duplicated cavities.
Device > SingleInsertConnector > InformationTable > ConnectorTable > AttributeOrderColumnSpecifies the display order for each attribute.
Device > SingleInsertConnector > InformationTable > ConnectorTable > AdditionalAttributesGenerationYes/NoSpecifies whether or not to generate additional attributes.
TableNameStringSpecifies the table name in which additional attributes are defined.
AttributeNameStringSpecifies the names of the attributes (names separated by comma) which need to be displayed in the conductor table.
SingleInsertConnector > InformationTable > PinMapGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

PositionInInformationTableTop/BottomSpecifies the position of the pin map symbol in the information table.
CatalogNameStringSpecifies the names of the catalog or chapter containing pin map symbol.
GroundStud > RepresentationType3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details(names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
GroundStud > InformationTable > PropertiesRelativePositionToRepresentationIntegerSpecifies the relative position of information table with respect to the representation.
VerticalCellMarginIntegerSpecifies the vertical distance between two items.
HorizontalCellMarginIntegerSpecifies the horizontal distance between two items.
GroundStud > InformationTable > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
GroundStud > InformationTable > FooterGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
GroundStud > InformationTable > ConnectorTable > PropertiesGenerationYes/NoSpecifies whether or not to generate an associated text template.
GenerateHeaderYes/NoSpecifies whether or not to generate an associated text template.
TableSplitIntegerSpecifies the number of lines in a table split.
SpaceBetweenTwoSplitIntegerSpecifies the space separating two splits of the table.
CellMarginIntegerSpecifies the margins value in a table cell.
DisplayUnitYes/NoSpecifies whether or not to generate an associated text template.
SortingAscending/DescendingSpecifies the sorting order.

Priority is always given to numbers. For alphanumeric initial, sorting is performed in alphabetical order and then in numeric order.

Important: The sorting is not case-sensitive.
DisplayEmptyCavityYes/NoSpecifies whether or not to display empty cavities in the table. When the parameters is set to Yes, a dash (-) appears in the corresponding cells.
MergeDuplicateCavityYes/NoSpecifies whether or not to merge cells corresponding to duplicated cavities.
GroundStud > InformationTable > ConnectorTable > AttributeOrderColumnSpecifies the display order for each attribute.
TerminalStrip > RepresentationType3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.
CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
TerminalStrip > InformationTable > PropertiesRelativePositionToRepresentationIntegerSpecifies the relative position of information table with respect to the representation.
VerticalCellMarginIntegerSpecifies the vertical distance between two items.
HorizontalCellMarginIntegerSpecifies the horizontal distance between two items.
TerminalStrip > InformationTable > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
TerminalStrip > InformationTable > FooterGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
TerminalStrip > InformationTable > ConnectorTable > PropertiesGenerationYes/NoSpecifies whether or not to generate an associated text template.
GenerateHeaderYes/NoSpecifies whether or not to generate an associated text template.
TableSplitIntegerSpecifies the number of lines in a table split.
SpaceBetweenTwoSplitIntegerSpecifies the space separating two splits of the table.
CellMarginIntegerSpecifies the margins value in a table cell.
DisplayUnitYes/NoSpecifies whether or not to generate an associated text template.
SortingAscending/DescendingSpecifies the sorting order.

Priority is always given to numbers. For alphanumeric initial, sorting is performed in alphabetical order and then in numeric order.

Important: The sorting is not case-sensitive.
DisplayEmptyCavityYes/NoSpecifies whether or not to display empty cavities in the table. When the parameters is set to Yes, a dash (-) appears in the corresponding cells.
MergeDuplicateCavityYes/NoSpecifies whether or not to merge cells corresponding to duplicated cavities.
TerminalStrip > InformationTable > ConnectorTable > AttributeOrderColumnSpecifies the display order for each attribute.
TerminalBlock > RepresentationType3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.
CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
TerminalBlock > InformationTable > PropertiesRelativePositionToRepresentationIntegerSpecifies the relative position of information table with respect to the representation.
VerticalCellMarginIntegerSpecifies the vertical distance between two items.
HorizontalCellMarginIntegerSpecifies the horizontal distance between two items.
TerminalBlock > InformationTable > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
TerminalBlock > InformationTable > FooterGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
TerminalBlock > InformationTable > ConnectorTable > PropertiesGenerationYes/NoSpecifies whether or not to generate an associated text template.
GenerateHeaderYes/NoSpecifies whether or not to generate an associated text template.
TableSplitIntegerSpecifies the number of lines in a table split.
SpaceBetweenTwoSplitIntegerSpecifies the space separating two splits of the table.
CellMarginIntegerSpecifies the margins value in a table cell.
DisplayUnitYes/NoSpecifies whether or not to generate an associated text template.
SortingAscending/DescendingSpecifies the sorting order.

Priority is always given to numbers. For alphanumeric initial, sorting is performed in alphabetical order and then in numeric order.

Important: The sorting is not case-sensitive.
DisplayEmptyCavityYes/NoSpecifies whether or not to display empty cavities in the table. When the parameters is set to Yes, a dash (-) appears in the corresponding cells.
MergeDuplicateCavityYes/NoSpecifies whether or not to merge cells corresponding to duplicated cavities.
Device > TerminalBlock > InformationTable > ConnectorTable > AttributeOrderColumnSpecifies the display order for each attribute.
Splice > Representation Type3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.
CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
Splice > InformationTable > PropertiesRelativePositionToRepresentationIntegerSpecifies the relative position of information table with respect to the representation.
VerticalCellMarginIntegerSpecifies the vertical distance between two items.
HorizontalCellMarginIntegerSpecifies the horizontal distance between two items.
Splice > InformationTable > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

OrientationStringSpecifies the orientation of the information table header for a splice.
CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
TextTemplateAlignmentLeft/RightSpecifies the alignment of the text template. By default, Left is selected.
Splice > InformationTable > ConnectorTable > PropertiesGenerationYes/NoSpecifies whether or not to generate an associated text template.
GenerateHeaderYes/NoSpecifies whether or not to generate an associated text template header.
GenerateCavityColumnYes/NoSpecifies whether or not to generate an associated cavity column.
TableSplitIntegerSpecifies the number of lines in a table split.
SpaceBetweenTwoSplitIntegerSpecifies the space separating two splits of the table.
CellMarginIntegerSpecifies the margins value in a table cell.
DisplayUnitYes/NoSpecifies whether or not to generate an associated text template.
SortingAscending/DescendingSpecifies the sorting order.

Priority is always given to numbers. For alphanumeric initial, sorting is performed in alphabetical order and then in numeric order.

Important: The sorting is not case-sensitive.
DisplayEmptyCavityYes/NoSpecifies whether or not to display empty cavities in the table. When the parameters is set to Yes, a dash (-) appears in the corresponding cells.
MergeDuplicateCavityYes/NoSpecifies whether or not to merge cells corresponding to duplicated cavities.
Splice > InformationTable > ConnectorTable > AttributeOrderColumnSpecifies the display order for each attribute.
Device > Splice > InformationTable > ConnectorTable > AdditionalAttributesGenerationYes/NoSpecifies whether or not to generate additional attributes.
TableNameStringSpecifies the table name in which additional attributes are defined.
AttributeNameStringSpecifies the names of the attributes (names separated by comma) which need to be displayed in the conductor table.
ConnectorShell > RepresentationType3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D detail (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D detail.
ConnectorShell > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.
BackShell > RepresentationType3Dprojection/2D detailSpecifies whether to generate a 3D representation or a 2D detail representing the device.

By default, the value is 3Dprojection.

2DDetailOrientationYes/NoSpecifies how to orient 2D detail. No (default value): 2D detail is oriented with respect to main drawing view. Yes: 2D detail is oriented with respect to segment tangency.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing 2D details (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
2DDetailNameStringSpecifies the name of the 2D details.
BackShell > HeaderGenerationYes/NoSpecifies whether or not to generate an associated text template.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing text templates (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TextTemplateNameStringSpecifies the name of the text template.

GreenLine

Parameter Value Description
LoopLine Display Yes/No Specifies whether or not to display the loop lines.
LineType Determines the line type used for the green line.
LineThicknessIntegerDetermines the line thickness used for the green line.
DistantLink DisplayYes/NoSpecifies whether or not to display the distant links.
LineTypeDetermines the line type used for the green line.
LineThicknessIntegerDetermines the line thickness used for the green line.
MechanicalPart DisplayYes/NoSpecifies whether or not to display the mechanical parts.
LineTypeDetermines the line type used for the green line.
LineThicknessIntegerDetermines the line thickness used for the green line.

Sheet

Parameter Value Description
Reports > Generation Generation Yes/No Specifies whether or not to generate reports.
Reports > Report Name Report Name String Specifies the report's name.
Reports > Properties Offset from frame borderIntegerSpecifies the offset value of the border frame.
Table splitIntegerSpecifies the number of lines in a table split.
Space between two splitIntegerSpecifies the space between two splits.
Space between two tablesintegerSpecifies the space between two tables.
Display line numberYes/NoSpecifies whether or not to display the line number.
Split optionHorizontal/VerticalSpecifies if a split is horizontal or vertical.
Report PositionTop/BottomSpecifies the position of a report.
Sheet Location-Specifies in which view the sheet appears.
ColorTableGenerationYes/NoSpecifies whether or not to generate the color code table.

By default, the value is No.

CatalogNameStringSpecifies the names of the catalog or chapter containing color table (names separated by semi-colon). The catalog is the one identified in the Electrical Manufacturing Preparation resources. If no catalog is specified, the system scans all catalogs defined in Electrical Manufacturing Preparation resources. It is recommended to use chapter names to improve search performance.
TableNameStringSpecifies the name of the color table.