Design Range Management

All commands of Shape Healing support Design Range Management.

When you create new content, you must specify the associated design range. Normal range is the default option and is sufficient in the majority of cases. For more information, see 3DEXPERIENCE Native Apps: Introducing Design Range Management.

Depending on the selected Design Range, the value of some parameters of Shape Healing commands are modified as follows.

Command Parameters Large Range Normal Range Small Range
Compare Distance 1mm 0.01mm 1e-004mm
Sag 0.1mm 0.01mm 1e-004mm
Step 1500mm 15mm 0.15mm
Compare & Review Distance 1.00mm 0.01mm 1.00mm
Sag 1.00mm 0.01mm 1.00mm
Step 2000.00mm 20.00mm 0.20mm
Face Checker Self-Intersection 0.1mm 0.001mm 1e-005mm
Hole 1mm 0.01mm 1e-004mm
Thin Face 0.1mm 0.001mm 1e-005mm
Face Orientation Search distance 10mm 0.1mm 0.001mm
Connection distance 1mm 0.01mm 1e-004mm
Surface Connection Checker Search distance 10mm 0.1mm 0.001mm
Connection distance 0.1mm 0.001mm 1e-005mm
Face Neighbors Connection distance 1mm 0.01mm 1e-004mm
Face Smooth Max Deformation 0.1mm 0.001mm 1e-005mm
Distance Min. 0mm 0mm 0mm
Distance Max. 0.1mm 0.001mm 1e-005mm
Curvature Max. 0.9 0.9 0.9
Suppress Curves Shorter than 0.1 0.001mm 1e-005mm
Local Join Join Merging Distance 0.001mm 0.001mm 0.001mm
Heal Merging Distance 0.001mm 0.001mm 0.001mm
Local Healing Distance Objective 0.1mm 0.001mm 1-e005mm
Boundary Options Threshold 0.1mm 0.001mm 1-e005mm