Automated Offset

This section describes the Automated Offset tables and how you can customize it.

This page discusses:

Overview

This section provides a brief overview of the Automated Offset tables.

The Automated Offset table defines the parameters when using the Automated Offset command. For more information see, Creating an Automated Offset.

In Data Setup, this table should be assigned to:

  • when using file-based tables, the Automated Offset item in the resource table of HVAC Design Resources.
  • when using Engineering Specification objects, a specification in the resource table of HVAC Specification Resources.

Table Description

This section describes the customization options of the Automated Offset tables.

File-Based Table

A typical Automated Offset file-based table is shown below.

V_EquivalentDiameterV_ShapeV_FluidV_DisciplineV_OffsetV_Angle

Engineering Specification Table

A typical HVAC Automated Offset Table is shown below:

Equivalent DiameterShapeMaterial Material CategoryFluid Fluid CategoryDisciplineOffsetAngle

The columns definitions are as follow:

Column NameColumn TypeLink to TableLink to Column
Equivalent DiameterNominal SizeDuct Reference DimensionEquivalent Diameter
ShapeStringDuct Reference DimensionShape
MaterialDS MaterialDuct Reference DimensionMaterial
Material CategoryStringDuct Reference DimensionMaterial Category
FluidStringFluidFluid
Fluid CategoryStringFluid Fluid Category
DisciplineString--
OffsetLength--
AngleAngle--

Sample Resource File

This section explains where to find the sample resource file.

The default location of XXX_XXX_AutomatedOffset.xls is

..\startup\EquipmentAndSystems\HVAC\Specification\

and then the relevant specification, such as SS150R.

Where Used

Used in this appWhenIs seen as
HVAC 3D DesignUsing the Automatic Offset command-