Height

This section describes the Height tables and how to customize it.

This page discusses:

Overview

This resource file is a discrete list of all possible height/diameter.

In Data Setup, this table should be assigned to:

  • when using file-based tables, the Height item in the resource table of HVAC Design Resources with a Standard criteria.
  • when using Engineering Specification objects, the Height item in the resource table of HVAC Specification Resources with a Standard criteria.

Table Description

To customize the table, enter all possible heights.

Important: You must create one table for each standard that you use.

File-Based Table

A typical Height file-based table is shown below:

100mm
200mm
300mm
400mm
500mm

Engineering Specification

A typical HVAC Height Table is shown below:

Height
100mm
200mm
300mm
400mm
500mm

The column definition is as follow:

Column NameColumn TypeLink to TableLink to Column
HeightLength--

The table has the following attribute:

  • Standard

Sample Resource File

This section explains where to find the sample resource file.

The default location of XXX_Height.xls is:

..\startup\EquipmentAndSystems\HVAC\

Where Used

Used in this appWhenIs seen as
HVAC 3D Part Designwhen creating a portAttributes in dialog box.