Duct Reference Dimension

This section describes the Duct Reference Dimension tables and how you can customize them. The Flexible Duct Reference Dimension table is also described.

This page discusses:

Overview

This section provides a brief overview of the Duct Reference Dimension tables.

The Duct Reference Dimension tables list all the ducts or other routable components available to the user within a duct specification.

The table shows all sizes and certain other parameters.

In Data Setup, this definition table should be assigned to:

  • when using file-based table, the Duct Reference Dimension item in the resource table of HVAC Design Resources.
  • when using Engineering Specification objects and depending on the usage:
    • the Duct Reference Dimension item in the resource table of HVAC Specification Resources.
    • a Parts Filter in a specification in the resource table of HVAC Specification Resources.

Table Description

This section describes the customization options of the Duct Reference Dimension table.

File-Based Table

The table appears when you click the Route Size Table button while routing. For each duct specification, you need to create a table listing the materials and other attributes permissible in your project.

A typical Rigid Duct Reference Dimension file-based table is shown below:

V_StandardV_EquivalentDiameterV_ShapeV_MaterialNameV_HeightV_WidthV_CornerRadiusV_WallThicknessV_MaxLength
100mm Rectangle Steel 100mm 300mm 0mm 5mm 0mm
200mm Rectangle Steel 200mm 500mm 0mm 5mm 0mm
100mm Rectangle Steel 100mm 300mm 20mm 5mm 0mm
200mm Rectangle Steel 200mm 500mm 20mm 5mm 0mm
100mm FlatOval Steel 100mm 300mm 0mm 5mm 0mm
200mm FlatOval Steel 200mm 500mm 0mm 5mm 0mm

To customize the table, enter a line in the spreadsheet for each standard, equivalent diameter, shape, height, and width that you use.

ParameterTypeImportanceInput / OutputDescription
V_StandardStringRequiredInputUsed for filtering
V_EquivalentDiameterStringRequiredInputUsed for filtering
V_ShapeStringRequiredInput
V_MaterialNameStringRequiredOutputThe material used for the duct. It will be applied if found in the material catalog.
HeightLengthRequiredInput
WidthLengthRequiredInput
V_CornerRadiusLengthRequiredInput
V_WallThicknessLengthOutput
V_MaxLengthLengthOutput

A typical Flexible Duct Reference Dimension file-based table is shown below:

V_StandardV_EquivalentDiameterV_MaterialNameV_OutsideDiameterV_WallThicknessV_MaxLength

To customize the table, enter a line in the spreadsheet for each standard and equivalent diameter, shape, height, and width that you use.

ParameterTypeImportanceInput / OutputDescription
V_StandardStringRequiredInputUsed for filtering
V_EquivalentDiameterStringRequiredInputUsed for filtering
V_MaterialNameStringOptionalThe material used for the pipe or tube. It will be applied if found in the material catalog.
V_OutsideDiameterLengthRequired
V_WallThicknessLengthRequired
V_MaxLengthLengthOptional
Note: Values in the Duct Reference Dimension tables are independent of the values you enter in the discrete list tables.
Important: Any material you specify in the Duct Reference Dimension table must exist in the database. There is a specific procedure for creating material - you must use this procedure and save the material in the database first. For more information, see the 3DEXPERIENCE Native Apps and the Material Definition User's Guide. The name in the DS_Material column must match the name in the database. Also note that material names in the database must be unique. If you have two entries with the name nickel in the database then, when you are routing a nickel duct, you will get an error message and material will not be applied to the duct.

A V_LinearWeight column can be added in this table listing linear weights. If this column is not defined in the table, the value of linear weight will be considered as zero.

Engineering Specification Table

Table

The table is used for attributes valuation on ducts when you create reference parts outside of specification context.

Equivalent DiameterShapeMaterialMaterial CategoryHeightWidthCorner RadiusWall ThicknessEnd StyleMaximum Length
100mm Rectangle Steel Steel 100mm 300mm 0mm 5mm 0mm
200mm Rectangle Steel Steel 200mm 500mm 0mm 5mm 0mm
100mm Rectangle Steel Steel 100mm 300mm 20mm 5mm 0mm
200mm Rectangle Steel Steel 200mm 500mm 20mm 5mm 0mm
100mm FlatOval Steel Steel 100mm 300mm 0mm 5mm 0mm
200mm FlatOval Steel Steel 200mm 500mm 0mm 5mm 0mm

The columns definitions are as follow:

Column NameColumn TypeLink to TableLink to Column
Equivalent DiameterNominal SizeEquivalent DiameterEquivalent Diameter
ShapeStringEquivalent DiameterShape
MaterialMaterialMaterialMaterial
Material CategoryStringMaterialMaterial Category
HeightLengthEquivalent DiameterHeight
WidthLengthEquivalent DiameterWidth
Corner RadiusLengthEquivalent DiameterCorner Radius
Wall ThicknessLength--
Maximum LengthLength--

The table has the following attribute:

  • Standard

Parts Filter

Parts Filter are used when you create ducts in a specification context.

Working in a specification context, Parts Filter are computed to give the duct allowed in the current specification instead of building a query on database or catalog from the duct reference dimension table.

Sample Resource File

This section explains where to find the sample resource file.

The default location of XXX_XXX_DuctReferenceDefinition.xls is

..\startup\EquipmentAndSystems\Duct\Specification\

and then the relevant specification, such as SS150R.

Where Used

Used in this appWhenIs seen as
HVAC 3D DesignRouting ducts-
HVAC 3D DesignModifying duct referenceDuct Reference Table