Insulation Part

This section describes the Insulation Part table and how you can customize it.

This page discusses:

Overview

This section provides a brief overview of the Insulation Part Definition table.

The Insulation Part table allows selection of insulation for ducts.

In Data Setup, this table should be assigned to the Insulation Part item in the resource table of HVAC Discipline Resources with a Specification criteria.

Table Description

This section describes the customization options of the Insulation Part table.

A typical Insulation Part table is shown below:

V_EquivalentDiameterV_ShapeV_WidthV_HeightV_CornerRadiusV_MinTemperatureV_MaxTemperatureV_InsulationTypeV_InsulationThickness

To customize the table, enter a line in the spreadsheet for each shape attributes and temperature range.

ParameterTypeImportanceDescription
V_EquivalentDiameterStringRequiredUsed for filtering
V_ShapeStringRequiredUsed for filtering
V_WidthLengthRequiredUsed for filtering
V_HeightLengthRequiredUsed for filtering
V_CornerRadiusStringRequiredUsed for filtering
V_MinTemperatureTemperatureRequiredUsed for filtering
V_MaxTemperatureTemperatureRequiredUsed for filtering
V_InsulationTypeStringRequiredProvides information for selection of the correct insulation.
V_InsulationThicknessLengthRequiredThe thickness for the duct size and temperature range
V_LinearWeightLengthOptionalLinear weights of insulation (0 if not set)

Sample Resource File

This section explains where to find the sample resource file.

The default location of XXX_XXX.InsulationReferenceDefinition.xls is

..\startup\EquipmentAndSystems\HVAC\InsulationSpecification.

Where Used

Used in this appWhenIs seen as
HVAC 3D DesignInsulating ductsTable Browser dialog box
HVAC Systems DesignCreating a Line IDDuct Insulation Specification list in Properties dialog box, Piping tab.