Min_NominalSize
|
String |
Specifies the minimum nominal size that a piping part, pipe or
insulation should have in order to be projected in a view, using the graphical
representation options defined in this GR_n node. Leaving the value blank means that
all values under the value specified for Max_NominalSize are
possible. By default, the value is
0in. |
Max_NominalSize |
String |
Specifies the maximum nominal size that a piping part, pipe or
insulation should have in order to be projected in a view, using the graphical
representation options defined in this GR_n node. Leaving the value blank means that
all values above the value specified for Min_NominalSize are
possible. By default, the value is
2in. |
|
3DProjection / 2DSymbol / NoProjection |
Specifies if a piping or tubing part should be projected as a 3D
projection, a 2D symbol or should not be projected. By default, the value
is 3DProjection. |
|
String |
Specifies the name of the drawing catalog or drawing chapter referenced in the
Piping/Tubing Design Resources resource set. There is no
default value. |
|
String |
Specifies the name of the symbol referenced by the drawing
catalog in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
Yes/No |
Specifies whether or not the text template should be projected in the view. By default, the value is No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the text template referenced by the drawing catalog in the
Piping/Tubing Design Resources resource set. There is no
default value. |
|
DoubleLine / SingleLine/NoProjection |
Specifies if a rigid pipe or tube should be projected using a
double line, a single line or should not be projected. By default, the
value is DoubleLine. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project a rigid pipe or tube. By default, the value is 1. |
|
Integer |
Specifies the line thickness (as defined in
) that should be used to project a rigid pipe or tube. By default, the value is 1. |
|
Yes/No |
Specifies whether or not the rigid branch ports are to be
shown. By default, the value is No. |
|
RGB Value |
Specifies the color that should be used to project a rigid pipe
or tube. By default, the value is
0,0,0. |
|
Yes/No |
Specifies whether or not an axis line should be used to project
a portion of a straight rigid pipe or tube. By default, the value is
No. Note:
If you set this parameter
No, make sure that, in the
Drafting node of the GVS file, the parameter is also set to No.
|
|
Real/Length |
Specifies the extension (extra) length applied to the axis line
from the extremities of a straight portion of a rigid pipe or tube. By default, the value is 1mm. |
|
Yes/No/Standard |
Specifies whether or not the intersection points of adjacent
rigid pipe or tube segments should be projected, or are acreated according to the
default drawing behavior. By default, the value is
Standard. |
|
Yes/No |
Specifies whether or not a number (corresponding to the position
in the rigid pipe or tube) should be projected next to the bend point. End Points is
also considered for Numbering if the option for
EndPoint is Yes. By default, the value is No. |
|
Yes/No |
Specifies wheter or not the two end points are created and
treated as manufacturing points (CornerBendPoint). If not, the End Point is not
automatically invisible. By default, the value is
No. |
|
Yes/No/Standard |
Specifies whether or not the center curve of a rigid pipe or
tube should be projected, or created according to the default drawing behavior. By default, the value is Standard. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project a center curve. By default, the value is 4. |
|
Yes/No |
Specifies whether or not a symbol should be projected at the
extremities of a rigid pipe or tube. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the symbol referenced by the drawing
catalog in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
Yes/No |
Specifies whether or not a text template should be used when
projecting a rigid pipe or tube. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the text template referenced by the
drawing catalog in the Piping/Tubing Design Resources
resource set. There is no default value. |
|
DoubleLine / SingleLine/NoProjection |
Specifies if a flexible pipe or tube should be projected using a
double line, a single line or should not be projected. By default, the
value is DoubleLine. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project a flexible pipe or tube. By default, the value is 1. |
|
Integer |
Specifies the line thickness (as defined in
) that should be used to project a flexible pipe or tube. By default, the value is 1. |
|
RGB Value |
Specifies the color that should be used to project a flexible
pipe or tube. By default, the value is
0,0,0. |
|
Real/Length |
Specifies the extension (extra) length applied to the axis line
from the extremities of a straight portion of a flexible pipe or tube. By default, the value is 1mm. |
|
Yes/No |
Specifies whether or not the intersection points of adjacent
flexible pipe or tube segments should be projected. By default, the value
is Yes. |
|
Yes/No |
Specifies whether or not a number (corresponding to the position
in the flexible pipe or tube) should be projected next to the bend point. By default, the value is No. |
|
Yes/No |
Specifies whether or not the center curve of a flexible pipe or
tube should be projected. By default, the value is
Yes. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project a center curve. By default, the value is 4. |
|
Yes/No |
Specifies whether or not a symbol should be projected at the
extremities of a flexible pipe or tube. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the symbol referenced by the drawing
catalog in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
Yes/No |
Specifies whether or not a text template should be used when
projecting a flexible pipe or tube. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the text template referenced by the
drawing catalog in the Piping/Tubing Design Resources
resource set. There is no default value. |
|
DoubleLine / SingleLine / NoProjection |
Specifies if an insulation should be projected using a double
line, a single line, or should not be projected. By default, the value is
DoubleLine. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project an insulation. By default, the value is 1. |
|
Integer |
Specifies the line thickness (as defined in
) that should be used to project an insulation. By default, the value is 1. |
|
Yes/No |
Specifies whether or not a 2D detail should be used when
projecting protection extremities. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the 2D detail referenced by the drawing
catalog in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
3DProjection / NoProjection |
Specifies whether an insulation on a piping or tubing part
should be projected as a 3D projection or should not be projected. By default, the value is 3DProjection. |
|
Integer |
Specifies the linetype (as defined in
) that should be used to project an insulation on a piping or tubing
part. By default, the value is 1. |
|
Integer |
Specifies the line thickness (as defined in
) that should be used to project an insulation. By default, the value is 1. |
|
Yes/No |
Specifies whether or not a text template should be used when
projecting an insulation. By default, the value is
No. |
|
String |
Specifies the name of the drawing catalog or drawing chapter
referenced in the Piping/Tubing Design Resources resource
set. There is no default value. |
|
String |
Specifies the name of the text template referenced by the
drawing catalog in the Piping/Tubing Design Resources
resource set. There is no default value. |