Min_NominalSize |
String |
Specifies the minimum nominal size that a piping part, pipe or insulation should have in order to be projected in a view, using the graphical representation options defined in this GR_n node.
Leaving the value blank means that all values under the value specified for Max_NominalSize are possible. By default, the value is 0in. |
Max_NominalSize |
String |
Specifies the maximum nominal size that a piping part, pipe or insulation should have in order to be projected in a view, using the graphical representation options defined in this GR_n node.
Leaving the value blank means that all values above the value specified for Min_NominalSize are possible. By default, the value is 2in. |
| 3DProjection / 2DSymbol / NoProjection | Specifies if a piping or tubing part should be projected as a 3D projection, a 2D symbol or should not be projected. By default, the value is 3DProjection. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the symbol referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| Yes/No | Specifies whether or not the text template should be projected in the view. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the text template referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| DoubleLine / SingleLine/NoProjection | Specifies if a rigid pipe or tube should be projected using a double line, a single line or should not be projected. By default, the value is DoubleLine. |
| Integer | Specifies the linetype (as defined in
) that should be used to project a rigid pipe or
tube. By default, the value is
1. |
| Integer | Specifies the line thickness (as defined in
) that should be used to project a rigid pipe or
tube. By default, the value is
1. |
|
Yes/No |
Specifies whether or not the rigid branch ports
are to be shown. By default, the value is
No. |
| RGB Value | Specifies the color that should be used to project a rigid pipe or tube. By default, the value is 0,0,0. |
| Yes/No | Specifies whether or not an axis line should be used to project a portion of a straight rigid pipe or tube. By default, the value is No. Note:
If you set this parameter No, make sure that, in the Drafting node of the GVS file, the parameter is also set to No.
|
| Real/Length | Specifies the extension (extra) length applied to the axis line from the extremities of a straight portion of a rigid pipe or tube. By default, the value is 1mm. |
| Yes/No/Standard | Specifies whether or not the intersection points of adjacent rigid pipe or
tube segments should be projected, or are created according to the
default drawing behavior. By default, the value is
Standard. |
| Yes/No | Specifies whether or not a number (corresponding to the position in the rigid
pipe or tube) should be projected next to the bend point. End Points
is also considered for Numbering if the
option for EndPoint is
Yes. By default, the value is
No. |
|
Yes/No |
Specifies wheter or not the two end points are
created and treated as manufacturing points (CornerBendPoint). If
not, the End Point is not automatically invisible. By default, the value is
No. |
| Yes/No/Standard | Specifies whether or not the center curve of a rigid pipe or tube should be
projected, or created according to the default drawing behavior. By default, the value is
Standard. |
| Integer | Specifies the linetype (as defined in
) that should be used to project a center curve. By default, the value is
4. |
| Yes/No | Specifies whether or not a symbol should be projected at the extremities of a rigid pipe or tube. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the symbol referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| Yes/No | Specifies whether or not a text template should be used when projecting a rigid pipe or tube. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing
chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
|
String |
Specifies the name of the text template referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| DoubleLine / SingleLine/NoProjection | Specifies if a flexible pipe or tube should be projected using a double line, a single line or should not be projected. By default, the value is DoubleLine. |
| Integer | Specifies the linetype (as defined in
) that should be used to project a flexible pipe or
tube. By default, the value is
1. |
| Integer | Specifies the line thickness (as defined in
) that should be used to project a flexible pipe or
tube. By default, the value is
1. |
| RGB Value | Specifies the color that should be used to project a flexible pipe or tube. By default, the value is 0,0,0. |
| Real/Length | Specifies the extension (extra) length applied to the axis line from the extremities of a straight portion of a flexible pipe or tube. By default, the value is 1mm. |
| Yes/No | Specifies whether or not the intersection points of adjacent flexible pipe or tube segments should be projected. By default, the value is Yes. |
| Yes/No | Specifies whether or not a number (corresponding to the position in the flexible pipe or tube) should be projected next to the bend point. By default, the value is No. |
| Yes/No | Specifies whether or not the center curve of a flexible pipe or tube should be projected. By default, the value is Yes. |
| Integer | Specifies the linetype (as defined in
) that should be used to project a center curve. By default, the value is
4. |
| Yes/No | Specifies whether or not a symbol should be projected at the extremities of a flexible pipe or tube. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the symbol referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| Yes/No | Specifies whether or not a text template should be used when projecting a flexible pipe or tube. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the text template referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| DoubleLine / SingleLine / NoProjection | Specifies if an insulation should be projected using a double line, a single line, or should not be projected. By default, the value is DoubleLine. |
| Integer | Specifies the linetype (as defined in
) that should be used to project an insulation. By default, the value is
1. |
| Integer | Specifies the line thickness (as defined in
) that should be used to project an insulation. By default, the value is
1. |
| Yes/No | Specifies whether or not a 2D detail should be used when projecting protection extremities. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the 2D detail referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |
| 3DProjection / NoProjection | Specifies whether an insulation on a piping or tubing part should be projected as a 3D projection or should not be projected. By default, the value is 3DProjection. |
| Integer | Specifies the linetype (as defined in
) that should be used to project an insulation on a
piping or tubing part. By default, the value is
1. |
| Integer | Specifies the line thickness (as defined in
) that should be used to project an insulation. By default, the value is
1. |
| Yes/No | Specifies whether or not a text template should be used when projecting an insulation. By default, the value is No. |
| String | Specifies the name of the drawing catalog or drawing chapter referenced in the Piping/Tubing Design Resources resource set. There is no default value. |
| String | Specifies the name of the text template referenced by the drawing catalog in the Piping/Tubing Design Resources resource set. There is no default value. |