Yes/No
|
Specifies whether axis of upward bends should be projected.
|
|
Color
|
Determines the color of the axis of upward bends.
|
|
Integer
|
Determines the linetype used for the axis of upward
bends.
|
|
Integer
|
Determines the thickness used for the axis of upward
bends.
|
|
Yes/No
|
Specifies whether the axis of downward bends should
be projected.
|
|
Color
|
Determines the color of the axis of downward bends.
|
|
Integer
|
Determines the linetype used for the axis of downward
bends.
|
|
Integer
|
Determines the thickness used for the axis of downward
bends.
|
|
Yes/No
|
Specifies whether the angle annotation of the bend
axis should be projected.
|
|
String
|
Specifies the prefix used for the angle annotation
of the bend axis. Angle is used as default value.
|
|
Internal/External
|
Specifies whether the annotation of the internal or
external angle should be projected.
|
|
Yes/No
|
Specifies whether the radius annotation of the bend
axis should be projected.
|
|
String
|
Specifies the prefix used for the radius annotation
of the bend axis. Radius is used as default value.
|
|
Yes/No
|
Specifies whether the annotation specifying the direction
of the bend should be projected.
|
|
String
|
Specifies the upward direction for the axis annotation.
|
|
String
|
Specifies the downward direction for the axis annotation.
|
|
Yes/No
|
Specifies whether BTLs (Bend Tangent Lines) should
be projected.
|
|
Color
|
Determines the color of BTLs.
|
|
Integer
|
Determines the linetype used for BTLs.
|
|
Integer
|
Determines the thickness used for BTLs.
|
| Yes/No
| Specifies whether or not to display two parts of the characteristic curves on the unfolded view of drawings, by breaking the curves for a given length from the start and end vertices of the wire. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Broken Display parameter is set to Yes. |
| Yes/No
| Specifies whether the clearance should be displayed or not. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Clearance parameter is set to Yes. |
| Yes/No
| Specifies whether the IML should
be projected.
|
| Color | Determines the color of the IML. |
| Integer | Determines the linetype used for the IML.
|
| Integer | Determines the thickness used for the IML. |
| Yes/No
| Specifies whether or not to display two parts of the characteristic curves on the unfolded view of drawings, by breaking the curves for a given length from the start and end vertices of the wire. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Broken Display parameter is set to Yes. |
| Yes/No
| Specifies whether the clearance should be displayed or not. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Clearance parameter is set to Yes. |
| Yes/No
| Specifies whether the OML should
be projected.
|
| Color | Determines the color of the OML. |
| Integer | Determines the linetype used for the OML.
|
| Integer | Determines the thickness used for the OML. |
| Yes/No
| Specifies whether or not to display two parts of the characteristic curves on the unfolded view of drawings, by breaking the curves for a given length from the start and end vertices of the wire. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Broken Display parameter is set to Yes. |
| Yes/No
| Specifies whether the clearance should be displayed or not. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Clearance parameter is set to Yes. |
| Yes/No
| Specifies whether the second OML should
be projected.
|
| Color | Determines the color of the second OML. |
| Integer | Determines the linetype used for the second OML.
|
| Integer | Determines the thickness used for the second OML. |
| Yes/No
| Specifies whether or not to display two parts of the characteristic curves on the unfolded view of drawings, by breaking the curves for a given length from the start and end vertices of the wire. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Broken Display parameter is set to Yes. |
| Yes/No
| Specifies whether the clearance should be displayed or not. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Clearance parameter is set to Yes. |
| Yes/No
| Specifies whether the CLB should
be projected.
|
| Color | Determines the color of the CLB. |
| Integer | Determines the linetype used for the CLB.
|
| Integer | Determines the thickness used for the CLB. |
| Yes/No
| Specifies whether or not to display two parts of the characteristic curves on the unfolded view of drawings, by breaking the curves for a given length from the start and end vertices of the wire. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Broken Display parameter is set to Yes. |
| Yes/No
| Specifies whether the clearance should be displayed or not. By default, the value is No. |
| Integer (in mm) | Specifies the distance to split the corresponding characteristic curve if the Clearance parameter is set to Yes. |