From the Automated
FEM section of the action bar, click Automated FEM
.
The Automated FEM panel
appears.
-
Click .
The Options panel appears.
-
Adjust the default prefix for FEM names by doing the following:
-
From the Options tree, click FEM
Name Prefix.
-
From the FEM Name Prefix options, click
Custom.
-
Select Product name to include the product name
in the prefix of the FEM name, select String, and
enter a custom string to include an additional custom word or phrase in
the prefix of the FEM name.
-
Adjust the default element quality checks by doing the following:
-
From the Options tree, click
Quality.
-
From the Quality analysis options, select
Choose a specific quality criteria set.
-
To select a quality criteria from a template, select a template type
from the list.
-
To select a quality criteria from the database, click
Database browser, and then search for the
criteria set from the top bar.
-
Click OK.
|