Discipline |
Defines the discipline in which you are working. You can choose between Piping & Tubing Design, Electrical Raceway Design or HVAC Design. If you switch from Piping & Tubing Design to another app,
the information are automatically updated. |
|
The property appears if you own the licences to at least two
disciplines. |
System |
Defines all the logical references having at least one line ID as child.
When you select a product or a part, the Context section
searches the first Ref-Ref "Implement" link inside the father of the activated
object in a bottom-up manner. The logical object that is referenced by the Ref-Ref
"Implement" link is the root from where the available systems are
obtained. |
|
The property appears if you are in an RFLP session. |
Line ID |
Defines all the line IDs available inside the current system. If the
activated object has a Ref-Ref "Implement" link to a line ID, only this line ID is
available for selection. If the activated object does not have a Ref-Ref
"Implement" link to a line ID, then all the line IDs that are available in the
system are listed. |
|
The property appears if you are in an RFLP session. |
Insulation Specification |
Defines the current insulation specification in use. If a line ID is set, the
value is set from the line ID. |
|
The property appears if you are in both: |
Specification |
Defines the current specification in use. If a line ID is set, the value is
set from the line ID. If no line ID is set, you choose between the default
specification or the no specification value. Note:
If you
select no specification, you must define the attributes
of the new pipe or tube.
|
|
The property appears if you are in either:
- Part Mode
- Manipulate Mode
- Spool Mode
- PCF Mode
|
Route Type |
Defines the route type to be used for the creation of a pipe
or tube. You can choose between
Rigid and Flexible. |
|
— |
Standard |
Defines the standard in use. If:
- A a specification is set, the available standards are listed from the
specification object attributes.
- No specification is set, the available standards are listed from the
standard table of the current resource set.
|
|
— |
Nominal Size |
Defines the nominal size in use. If:
- A specification is set, the available nominal sizes are taken from the
Nominal Size table of the specification.
- No specification is set, the available nominal sizes are taken from the
Nominal Size table of the current resource set.
Note:
The Nominal size sorting inside DIP option defines
the sorting order of the nominal size. It is specified by your administrator in
the Preferences.
|
|
The property appears if you are in either:
- Part Mode
- Manipulate Mode
- Spool Mode
- PCF Mode
|