From the Setup section of the action bar,
click Process Settings
.
- Optional:
Enter a value for the Melt temperature, which is the temperature
of the polymer entering the model at the injection locations.
- Optional:
Enter a value for the Mold temperature, which is the uniform
temperature of the cavity walls.
- Optional:
Enter a value for the Fill time, which is the time required to
inject all of the plastic material into the mold.
The deafult filling time is 1/10 of the automatic cooling time
, as determined by the following equation:
where
is the average thickness;
is the heat conductivity (expressed as density times specific heat);
and
,
, and
are the melt temperature, mold temperature, and ejection temperature,
respectively.
- Optional:
Enter a value for the Injection pressure limit, which is the
maximum pressure that the injection machine can produce.
The default setting, 100 MPa, is the same for all simulations.
-
Click OK.
|