Build Process Rules

The Build Process Rules options let you customize default build process rules for Additive Part Preparation.

This page discusses:

Recoater

Pending Time Before Recoating
Specifies the default time before the powder is spread across the build chamber.

By default, Pending Time Before Recoating is set to 0s.

Recoating Time
Specifies the default time in which the powder is completely spread.

By default, Recoating Time is set to 0s.

Recoating Breakthrough
Specifies the default time in which the roller stops.

By default, Recoating Breaktime is set to 0s.

Pending Time After Recoating
Specifies the default time before scanning the slices.

By default, Pending Time After Recoating is set to 0s.

Chamber

Start Temperature
Specifies the default machine temperature when the additive process starts.

By default, Start Temperature is set to 298K°C.

Gas Inlet Detection
Specifies the default direction of the gas.

By default, Gas Inlet Detection is set along the x-axis (value = 0).

Gas Flow
Specifies the default flow of the gas inlet.

Scanning

Scanning Iteration of First Slice
Specifies the default number of scans on the first level.

By default, Scanning Iteration of First Slice is set to 1.

Part Order Scanning
Specifies the default part order scanning sequence.
Order Scan Paths
Specifies the default scan path order.
Support First
When selected, scans the supports first by default.

By default, Support First is not selected.