Recoater
- Pending Time Before Recoating
- Specifies the default time before the powder is spread across the
build chamber.
By default, Pending Time Before
Recoating is set to 0s.
- Recoating Time
- Specifies the default time in which the powder is completely
spread.
By default, Recoating Time is set
to 0s.
- Recoating Breakthrough
- Specifies the default time in which the roller stops.
By default, Recoating Breaktime is
set to 0s.
- Pending Time After Recoating
- Specifies the default time before scanning the slices.
By default, Pending Time After
Recoating is set to 0s.
Chamber
- Start Temperature
- Specifies the default machine temperature when the additive process
starts.
By default, Start Temperature is
set to 298K°C.
- Gas Inlet Detection
- Specifies the default direction of the gas.
By default, Gas Inlet Detection is
set along the x-axis (value = 0).
- Gas Flow
- Specifies the default flow of the gas inlet.
Scanning
- Scanning Iteration of First Slice
- Specifies the default number of scans on the first level.
By default, Scanning Iteration of First
Slice is set to 1.
- Part Order Scanning
- Specifies the default part order scanning sequence.
- Order Scan Paths
- Specifies the default scan path order.
- Support First
- When selected, scans the supports first by default.
By default, Support First is not
selected.
|