Discipline |
Defines the discipline in which you are working. You can choose between Piping & Tubing Design, Electrical Raceway Design or HVAC Design. If you switch from Electrical Raceway Design to another app,
the information are automatically updated. |
|
The property appears if you own the licences to at least two
disciplines. |
Cableway |
Defines the cableway in use. |
|
— |
Specification |
Defines the current specification in use. If a line ID is set, the value is
set from the line ID. If no line ID is set, you choose between the default
specification or the no specification value. Note:
If you
select no specification, you must define the attributes
of the new tray.
|
|
The property appears if you are in either:
- Part Mode
- Manipulate Mode
- Spool Mode
- PCF Mode
|
Standard |
Defines the standard in use. If:
- A a specification is set, the available standards are listed from the
specification object attributes.
- No specification is set, the available standards are listed from the
standard table of the current resource set.
|
|
— |
Shape |
Defines the shape of the selected tray. You can choose between
Circle, H and
U. |
|
— |
Nominal Size |
Defines the nominal size in use. If:
- A specification is set, the available nominal sizes are taken from the
Nominal Size table of the specification.
- No specification is set, the available nominal sizes are taken from the
Nominal Size table of the current resource set.
Note:
The Nominal size sorting inside DIP option defines
the sorting order of the nominal size. It is specified by your administrator in
the Preferences.
|
|
The property appears if you are in either:
- Part Mode
- Manipulate Mode
- Spool Mode