ABQ_EChemPET_Electrode_Particle_PowerLoss

This parameter table type is used in modeling the electrochemical process in a battery to specify the joule heat fraction losses at the microscale particle-electrolyte interface and due to entropy generation.

This page discusses:

You must include a parameter table of type "ABQ_EChemPET_Electrode_Particle_PowerLoss" in the material definition to specify the joule heat fraction losses at the microscale particle-electrolyte interface and due to entropy generation.

Parameter Table Type Definition

PARAMETER TABLE TYPE, NAME="ABQ_EChemPET_Electrode_Particle_PowerLoss", PARAMETERS=2
 FLOAT, 0.0, "
						
							β
							1
						
					", , ,
 FLOAT, 0.0, "
						
							β
							2
						
					", , ,
 

Parameters

β 1
Fraction of ohmic loss at the solid-liquid interface.

Default value is zero.

β 2
Fraction of entropy generation.