Command
aStudy.gather (request= , results= , step= , frameValue= | inc= | mode= , variable= , additional data)
Required Data
-
results
-
Set results equal to a name that will be used to
identify the results record gathered by this command. This name must be
enclosed in matching quotation marks.
-
variable
-
Set variable equal to an output variable identifier
key; this key must be enclosed in matching quotation marks.
For gathering results from the results (.fil) file only
those output variable identifier keys appearing under the
.fil column heading in
Abaqus/Standard Output Variable Identifiers
or
Abaqus/Explicit Output Variable Identifiers
are available. For example, the U or
S variable identifier keys can be specified, but
the U1 or S11
variable identifier keys cannot be specified. In addition, the
MODAL variable identifier key can be specified
to gather frequency results (those written to the results file with the record
key 1980); in this case no additional data are required in this command.
When gathering results from the output database (.odb)
file, each result record to be gathered is chosen by specifying one of the
available output variable identifier keys appearing under the
.odb column heading in
Abaqus/Standard Output Variable Identifiers
or
Abaqus/Explicit Output Variable Identifiers.
For field output the component must not be specified, while for history output
the component number is required; for example, the
U or S variable
identifier keys can be specified for field output, while the
U1 or S11 variable
identifier keys can be specified for history output.
Optional Data
-
request
-
This option is applicable only if the results are to be gathered from the
output database file.
Set request equal to
FIELD or
HISTORY to specify whether the results must be
gathered from the field data or the history data in the output database file.
If request is omitted from this command, the
results will be gathered from the field data.
-
step
-
Set step equal to the analysis step number from
which the results are to be gathered.
If step is specified in this command as well as in
the output command, the
step specification in this command is used.
If step is omitted from this command, it must have
been specified in the output command.
Optional and Mutually Exclusive Data
-
frameValue
-
This option is applicable only if the results are to be gathered from the
output database file.
Set frameValue equal to the step time or frequency
value of the analysis increment in the analysis step specified from which the
results are to be gathered. frameValue can also be set
equal to the symbolic constant LAST to specify
that results are to be gathered from the last increment of the step. If no
results are available at the frameValue specified, a
warning will be issued and the results will be gathered from the closest
increment.
If frameValue is specified in this command as well
as in the output command, the
frameValue specification in this command is used for
gathering.
If frameValue is omitted from this command, the
results are gathered for the frameValue specified in
the output command or are gathered from the last
increment in the step.
-
inc
-
Set inc equal to the number of the analysis
increment of the non-frequency analysis step specified from which the results
are to be gathered across the parametric study variations.
inc can also be set equal to the symbolic constant
LAST to specify that results are to be
gathered from the last increment of the step.
If inc is specified in this command as well as in
the output command, the
inc specification in this command is used for
gathering.
If inc is omitted from this command, the results
are gathered from the increment specified in the
output command or are gathered from the last
increment in the step.
This option is not valid for gathering history results from the output
database file.
-
mode
-
Set mode equal to the number of the mode of the
frequency analysis step specified from which the results are to be gathered
across the parametric study variations.
If mode is specified in this command as well as in
the output command, the
mode specification in this command is used.
If mode is omitted from this command, the results
are gathered from the mode specified in the
output command or are gathered from the first
mode in the step.
Additional Data for Element Integration Point Variables
Required Data
-
element
-
Set element equal to the number of the element for
which results are to be gathered.
-
instance
-
This option is required only if results are gathered for an element on a
part instance in an output database file generated from a model described as an
assembly of part instances.
Set instance equal to the name of the part instance
for which results are to be gathered. This name must be enclosed in matching
quotation marks.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Optional Data
-
centroid
-
Set centroid equal to the symbolic constant
ON to indicate that the results are to be
gathered at the centroid of the element. This option is valid only when the
results have been written to the results file at the centroid of the element.
centroid, int, and
node are mutually exclusive.
If centroid, int, and
node are omitted, the default is
int=1.
-
int
-
Set int equal to the number of the integration
point of the element for which results are to be gathered. This option is valid
only when the results have been written to the results file at the integration
points of the element.
centroid, int, and
node are mutually exclusive.
If int is omitted, the default is
int=1. If centroid,
int, and node are omitted,
the default is int=1.
-
node
-
Set node equal to the number of the node in the
element for which results are to be gathered. This option is valid only when
the results have been written to the results file at the nodes of the element.
centroid, int, and
node are mutually exclusive.
If centroid, int, and
node are omitted, the default is
int=1.
-
rbnum
-
Set rbnum equal to the number of the rebar for
which results are to be gathered. The rebar number is consistent with the
order, per element, in which you define the rebar (see
Defining Rebar as an Element Property).
If rbnum is omitted, the default is
rbnum=1.
Rebar information cannot be gathered from the output database file.
-
rebar
-
Set rebar equal to the name of the rebar for which
results are to be gathered (defined as described in
Defining Rebar as an Element Property).
Rebar results can be obtained for continuum and beam elements only at
integration points; for shell and membrane elements rebar results can be
obtained at integration points and at the centroid of the element.
Rebar information cannot be gathered from the output database file.
-
section
-
Set section equal to the number of the section
point of the element for which results are to be gathered. This applies to
beam, shell, or layered solid elements. section is not
relevant for rebar results.
If section is omitted, the default is
section=1.
Additional Data for Element Section Variables
Required Data
-
element
-
Set element equal to the number of the element for
which results are to be gathered.
-
instance
-
This option is required only if results are gathered for an element on a
part instance in an output database file generated from a model described as an
assembly of part instances.
Set instance equal to the name of the part instance
for which results are to be gathered. This name must be enclosed in matching
quotation marks.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Optional Data
-
centroid
-
Set centroid equal to the symbolic token
ON to indicate that the results are to be
gathered at the centroid of the element. This option is valid only when the
results have been written to the results file or output database at the
centroid of the element.
centroid, int, and
node are mutually exclusive.
If centroid, int, and
node are omitted, the default is
int=1.
-
int
-
Set int equal to the number of the integration
point of the element for which results are to be gathered. This option is valid
only when the results have been written to the results file or output database
at the integration points of the element.
centroid, int, and
node are mutually exclusive.
If int is omitted, the default is
int=1. If centroid,
int, and node are omitted,
the default is int=1.
-
node
-
Set node equal to the number of the node in the
element for which results are to be gathered. This option is valid only when
the results have been written to the results file or output database at the
nodes of the element.
centroid, int, and
node are mutually exclusive.
If centroid, int, and
node are omitted, the default is
int=1.
Additional Data for Whole Element Variables
Required Data
-
element
-
Set element equal to the number of the element for
which results are to be gathered.
-
int
-
Set int = –1.
-
instance
-
This option is required only if results are gathered for an element on a
part instance in an output database file generated from a model described as an
assembly of part instances.
Set instance equal to the name of the part instance
for which results are to be gathered. This name must be enclosed in matching
quotation marks.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Additional Data for Partial Model (Element Set) or Whole Model Variables
Optional Data
-
elset
-
Set elset equal to the element set name for which
results are to be gathered. If elset is omitted,
results will be gathered for the whole model. This name must be enclosed in
matching quotation marks.
-
instance
-
This option is required only if results are gathered from an output database
file and if the element set is defined on an instance.
Set instance equal to the name of the instance on
which the element set is defined. This name must be enclosed in matching
quotation marks.
If the element set is defined on the assembly,
instance must not be specified in both this command
and the output command.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Additional Data for Nodal Variables
Required Data
-
node
-
Set node equal to the number of the node for which
results are to be gathered.
-
instance
-
This option is required only if results are gathered for a node on a part
instance in an output database file generated from a model described as an
assembly of part instances.
Set instance equal to the name of the instance for
which results are to be gathered. This name must be enclosed in matching
quotation marks.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Additional Data for Modal Variables
Additional Data for Contact Surface Variables
Additional Data for Cavity Radiation Surface Variables
Required Data
-
element
-
Set element equal to the number of the element
underlying the cavity facet for which results are to be gathered.
-
elface
-
Set elface equal to the face identifier of the face
of the element underlying the cavity facet for which results are to be
gathered.
-
instance
-
This option is required only if results are gathered from an output database
file generated from a model described as an assembly of part instances.
Set instance equal to the name of the part instance
for which results are to be gathered. This name must be enclosed in matching
quotation marks.
If instance is specified in this command as well as
in the output command, the
instance specification in this command is used.
Additional Data for Section File Output
Required Data
-
sectionName
-
Set sectionName equal to the name of the section
for which results are to be gathered. This name must be enclosed in matching
quotation marks (see
Section Output from Abaqus/Standard).
|