ProductsAbaqus/Standard
TypeModel data
LevelPartPart instanceAssembly
Required parameters
- ELSET
-
Set this parameter equal to the name of the element set containing the ITT-, ISL-, IRS-, and ASI-type contact elements for which properties are being defined.
Optional parameters
- NAME
-
Set this parameter equal to a label that will be used to refer to this interface definition. The label given can be used to identify this particular interface definition in user subroutines such as GAPCON.
Data line for ITT-type elements
- First (and only) line
Radial clearance between the pipes.
There are no data lines for ISL21A and ISL22A elements
There are no data lines for IRS-type elements for use with axisymmetric elements
Data line for ASI1 elements
- First (and only) line
Area associated with the elements.
- Enter the direction cosine, in terms of the global Cartesian coordinate system, of the interface normal that points into the acoustic fluid:
X-direction cosine.
Y-direction cosine.
Z-direction cosine.
Data line for ASI-type elements for use with 2D elements
- First (and only) line
Element thickness. The default is unit thickness.
There are no data lines for ASI-type elements for use with axisymmetric elements or 3D elements