Required parameters- COMPONENT
Set this parameter equal to the connector's component number for which a failure criterion is
defined in Abaqus/Standard; only an available component of relative motion can be chosen. In Abaqus/Explicit any connector component number can be specified.
Optional parameters- RELEASE
In
Abaqus/Standard
set this parameter equal to ALL (default) to release all available components of relative
motion when the failure criterion is satisfied. In
Abaqus/Explicit
set this parameter equal to ALL (default) to release all components (available or constrained)
when the failure criterion is satisfied.
In
Abaqus/Standard
set this parameter equal to an available component of relative motion number to
release only that component when the failure criterion is satisfied. In
Abaqus/Explicit
set this parameter equal to a component number to release only that component
when the failure criterion is satisfied.
Data line
to define the failure criterion- First (and only) line
Lower bound on the connector's component of relative position specified by
the COMPONENT parameter. If not specified, no lower bound is used for the
selected component.
Upper bound on the connector's component of relative position specified by
the COMPONENT parameter. If not specified, no upper bound is used for the
selected component.
Lower bound on the force or moment in the direction of the component of
relative motion indicated by the COMPONENT parameter. If not specified, no lower bound is used for the
selected force or moment.
Upper bound on the force or moment in the direction of the component of
relative motion indicated by the COMPONENT parameter. If not specified, no upper bound is used for the
selected force or moment.
|