|   
Optional parameters 
ALPHA 
Set this parameter equal to the 
  factor to create Rayleigh mass proportional damping in the following
  procedures: 
 The default is ALPHA=0. (Units of
  T−1.) 
 In 
  Abaqus/Standard
  set ALPHA=TABULAR to specify that the mass proportional viscous damping is
  dependent on temperature. 
 In 
  Abaqus/Explicit
  set ALPHA=TABULAR to specify that the mass proportional damping is dependent on
  temperature and/or field variables. 
            BAND LIMITED
          
            This parameter applies only to Abaqus/Explicit analyses.  Set this parameter equal to the damping ratio, 
                
              , used in the band-limited damping. The default is
                BAND LIMITED=0. Set
              BAND LIMITED=TABULAR
              to specify that the damping ratio in band-limited damping is dependent on temperature
              and/or field variables. BETA 
Set this parameter equal to the 
  factor to create Rayleigh stiffness proportional damping in the following
  procedures: 
 The default is BETA=0. (Units of T.) 
 In 
  Abaqus/Standard
  set BETA=TABULAR to specify that the stiffness proportional viscous damping is
  dependent on temperature. 
 In 
  Abaqus/Explicit
  set BETA=TABULAR to specify that the stiffness proportional damping is
  dependent on temperature and/or field dependent variables. 
COMPOSITE 
This parameter applies only to 
  Abaqus/Standard
  analyses. 
 Set this parameter equal to the fraction of critical damping to be used with
  this material in calculating composite damping factors for the modes. Composite
  damping is used in mode-based procedures that follow subspace iteration
  eigenvalue extraction or eigenvalue extraction using the Lanczos eigensolver
  with SIM=NO,
  except for 
  STEADY STATE DYNAMICS, SUBSPACE PROJECTION. Use the 
  MODAL DAMPING, VISCOUS=COMPOSITE option to activate composite modal damping. 
 The default is COMPOSITE=0. 
DEPENDENCIES 
This parameter applies only to 
  Abaqus/Explicit
  analyses when ALPHA=TABULAR and/or BETA=TABULAR. 
 Set this parameter equal to the number of field variables included in the
  definition of the 
  and/or 
  factors, in addition to temperature. If this parameter is omitted, it is
  assumed that Rayleigh damping is constant or depends only on temperature.
  See 
  Specifying Field Variable Dependence
  for more information. 
            HIGH FREQUENCY CUTOFF
          
            This parameter applies only to Abaqus/Explicit analyses and is valid only when the
              BAND LIMITED parameter is used.  Set this parameter equal to the frequency value, 
                
              , to define the upper limit of the frequency range. (Units of
              cycles/time.)
            LOW FREQUENCY CUTOFF
          
            This parameter applies only to Abaqus/Explicit analyses and is valid only when the
              BAND LIMITED parameter is used.  Set this parameter equal to the frequency value, 
                
              , to define the lower limit of the frequency range. (Units of
              cycles/time.)STRUCTURAL 
Set this parameter equal to the 
  factor to create stiffness proportional structural damping in the following
  procedures: 
 The default is STRUCTURAL=0. 
 In 
  Abaqus/Standard
  set STRUCTURAL=TABULAR to specify that the stiffness proportional structural damping
  is dependent on temperature. 
Data lines to
define temperature and/or field variable-dependent mass proportional damping (ALPHA=TABULAR) in 
Abaqus/Explicit 
First line  
 
.
  (Units of T−1.) 
 
Temperature. 
 
First field variable. 
 
Second field variable. 
 
Etc., up to six field variables. 
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six) 
Seventh field variable. 
 
Etc., up to eight field variables per line. 
 Repeat this set of data
lines as often as necessary to define the alpha damping as a function of
temperature and other predefined field
variables.Data lines to define
temperature-dependent mass proportional viscous damping (ALPHA=TABULAR) in 
Abaqus/StandardFirst line  
.
  (Units of T−1.) 
 
Temperature. 
 Repeat this data line as
often as necessary to define the alpha damping as a function of
temperature.Data lines to define a temperature and/or field variable-dependent damping
        ratio in band-limited damping
        (BAND LIMITED=TABULAR)
        in Abaqus/Explicit
        
          First line
            
              
                    
                  . Temperature. First field variable. Second field variable. Etc., up to six field variables. Subsequent lines (only needed if the
            DEPENDENCIES parameter has a value
            greater than six)
            
              Seventh field variable. Etc., up to eight field variables per line.  Repeat this set of data lines as often as necessary to define the
              damping ratio as a function of temperature and other predefined field
              variables.Data lines to
define temperature and/or field variable-dependent stiffness proportional
damping (BETA=TABULAR) in 
Abaqus/ExplicitFirst line  
.
  (Units of T.) 
 
Temperature. 
 
First field variable. 
 
Second field variable. 
 
Etc., up to six field variables. 
Subsequent lines
(only needed if the DEPENDENCIES parameter has a value greater than six) 
Seventh field variable. 
 
Etc., up to eight field variables per line. 
 Repeat this set of
data lines as often as necessary to define the beta damping as a function of
temperature and other predefined field
variables.
Data lines to define
temperature-dependent stiffness proportional viscous damping (BETA=TABULAR) in 
Abaqus/StandardFirst line  
.
  (Units of T.) 
 
Temperature. 
 Repeat this data line as
often as necessary to define the stiffness proportional viscous damping as a
function of temperature.Data
lines to define temperature-dependent stiffness proportional structural damping (STRUCTURAL=TABULAR) in 
Abaqus/StandardFirst line  
.
  
 
Temperature. 
 Repeat this data line as often as necessary to define the
structural damping as a function of temperature.Data lines to
define both temperature and/or field variable-dependent mass and stiffness
proportional damping (both ALPHA=TABULAR and BETA=TABULAR) in 
Abaqus/Explicit 
First line  
 
.
  (Units of T−1.) 
 
.
  (Units of T.) 
 
Temperature. 
 
First field variable. 
 
Second field variable. 
 
Etc., up to five field variables. 
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five) 
Sixth field variable. 
 
Etc., up to eight field variables per line. 
 Repeat this set
of data lines as often as necessary to define the alpha and beta damping as a
function of temperature and other predefined field
variables.Data lines to define both temperature and/or field variable-dependent mass
        proportional damping and band-limited damping (both
        ALPHA=TABULAR
        and
        BAND LIMITED=TABULAR)
        in Abaqus/Explicit
        
          First line
            
              
                    
                  . (Units of T−1.) 
                    
                  .Temperature. First field variable. Second field variable. Etc., up to five field variables. Subsequent lines (only needed if the
            DEPENDENCIES parameter has a value
            greater than five)
            
              Sixth field variable. Etc., up to eight field variables per line.  Repeat this set of data lines as often as necessary to define the
              mass proportional and band-limited damping as a function of temperature and other
              predefined field variables.Data lines to define both temperature and/or field variable-dependent stiffness
        proportional damping and band-limited damping (both
        BETA=TABULAR
        and
        BAND LIMITED=TABULAR)
        in Abaqus/Explicit
        
          First line
            
              
                    
                  . (Units of T.)
                
                    
                  .Temperature. First field variable. Second field variable. Etc., up to five field variables. Subsequent lines (only needed if the
            DEPENDENCIES parameter has a value
            greater than five)
            
              Sixth field variable. Etc., up to eight field variables per line.  Repeat this set of data lines as often as necessary to define the
              stiffness proportional and band-limited damping as a function of temperature and other
              predefined field variables.Data lines to define temperature and/or field variable-dependent mass
        proportional, stiffness proportional, and band-limited damping
        (ALPHA=TABULAR,
        BETA=TABULAR,
        and
        BAND LIMITED=TABULAR)
        in Abaqus/Explicit
        
          First line
            
              
                    
                  . (Units of T−1.) 
                    
                  . (Units of T.)
                
                    
                  .Temperature. First field variable. Second field variable. Etc., up to four field variables. Subsequent lines (only needed if the
            DEPENDENCIES parameter has a value
            greater than four)
            
              Fifth field variable. Etc., up to eight field variables per line.  Repeat this set of data lines as often as necessary to define the
              mass proportional, stiffness proportional, and band-limited damping as a function of
              temperature and other predefined field variables. |