Set this parameter equal to the number of field variable dependencies included in the
definition of the fluid leak-off coefficients, in addition to temperature. If this
parameter is omitted, it is assumed that the leak-off coefficients are constant or
depend only on temperature. See Material Data Definition for more information.
USER
Include this parameter to indicate that user subroutine UFLUIDLEAKOFF will be used to
define the fluid leak-off coefficients.
Data lines to define fluid leak-off coefficients if the
USER parameter is omitted
First line
Fluid leak-off coefficient at top element surface.
Fluid leak-off coefficient at bottom element surface.
Temperature.
First field variable.
Etc., up to six field variables.
Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than six)
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to specify
K as a function of temperature and field
variables.
There are no data lines when the
USER parameter is included