*FLUID PIPE THERMAL

Define the method to solve for the convective heat transfer solution in the thermal fluid pipe elements.

This option is used to define whether a constant flux or constant temperature solution method is chosen for the convective heat transfer solution. It can be used only in conjunction with the FLUID PIPE SECTION option.

This page discusses:

Required parameters

TYPE
SET TYPE=FLUX to define a constant flux solution for convective heat transfer.

SET TYPE=TEMPERATURE to define a constant temperature solution for convective heat transfer.

There are no data lines associated with this option.