Use this parameter to choose a contact pressure-overclosure relationship
other than the default hard contact.
Set PRESSURE-OVERCLOSURE=HARD (default) to choose a pressure-overclosure relationship
without physical softening. Note that some numerical softening will occur if a
penalty or augmented Lagrange constraint enforcement method is used.
Set PRESSURE-OVERCLOSURE=EXPONENTIAL to define an exponential pressure-overclosure relationship.
Set PRESSURE-OVERCLOSURE=LINEAR to define a linear pressure-overclosure relationship.
Set PRESSURE-OVERCLOSURE=SCALE FACTOR to define a piecewise linear pressure-overclosure relationship
based on scaling the default contact stiffness. This option is available only
for the general contact algorithm in
Abaqus/Explicit.
Set PRESSURE-OVERCLOSURE=TABULAR to define a piecewise linear pressure-overclosure relationship
in tabular form.
Set PRESSURE-OVERCLOSURE=HERTZ to define a Hertz-type pressure-overclosure relationship for
discrete element method analysis.
Set PRESSURE-OVERCLOSURE=JKR to define a JKR-type pressure-overclosure relationship for discrete element
method analysis.
Set PRESSURE-OVERCLOSURE=LKM to define contact for lumped kinetic molecular method
analysis.
If a contact area is not defined, such as may occur for node-based surfaces
or for GAP- or ITT-type contact elements, “pressure” should be interpreted as force.
For contact with three-dimensional beams or trusses, “pressure” should be
interpreted as force per unit length.
When used to modify the default surface behavior, the PRESSURE-OVERCLOSURE parameter cannot be used with the NO SEPARATION parameter in an
Abaqus/Standard
analysis.