Time Increment and Mass Output

The DT and DMASS variables are always written when any results file output is requested. You can request output of the time increment and the steady-state detection variables SSPEEQ, SSSPRD, SSFORC, and SSTORQ to the output database.

The output variables listed below are available in Abaqus/Explicit.

DT
.fil: yes   .odb Field: no   .odb History: yes  

Time increment.

DMASS
.fil: yes   .odb Field: no   .odb History: yes  

Percent change in mass of the model due to mass scaling.

SSPEEQ
.fil: no   .odb Field: no   .odb History: yes  

Steady-state equivalent plastic strain norms.

SSPEEQn
.fil: no   .odb Field: no   .odb History: yes  

Steady-state equivalent plastic strain norm n.

SSSPRD
.fil: no   .odb Field: no   .odb History: yes  

Steady-state spread strain norms.

SSSPRDn
.fil: no   .odb Field: no   .odb History: yes  

Steady-state spread norm n.

SSFORC
.fil: no   .odb Field: no   .odb History: yes  

Steady-state force norms.

SSFORCn
.fil: no   .odb Field: no   .odb History: yes  

Steady-state force norm n.

SSTORQ
.fil: no   .odb Field: no   .odb History: yes  

Steady-state torque norms.

SSTORQn
.fil: no   .odb Field: no   .odb History: yes  

Steady-state torque norm n.