Section Variables

You can request section variables as section output to the data or results file or as integrated output to the output database.

By default, all components of forces and moments are given with respect to the global system. If a local coordinate system is defined for the output request, all components are given with respect to the local system. The output quantity is computed by integration over a surface that is specified either directly in the output request or by associating an integrated output section definition with the integrated output request.

Different output variables are available depending on the type of analysis. For coupled analyses the appropriate combination of variables can be requested. For example, in a coupled thermal-electrical analysis both SOH and SOE are valid output requests. Section output variables are not available for linear dynamic procedures.

This page discusses:

The output variables listed below are available in Abaqus/Standard.

All Analysis Types

SOAREA
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Area of the defined section.

Stress/Displacement Analysis

SOF
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total force in the section.

SOM
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total moment in the section.

SOCF
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Center of the total force in the section.

Heat Transfer Analysis

SOH
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total heat flux associated with the section.

Electrical Analysis

SOE
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total current associated with the section.

Mass Diffusion Analysis

SOD
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total mass flow associated with the section.

Coupled Pore Fluid Diffusion-Stress Analysis

SOP
.dat: yes   .fil: yes   .odb Field: no   .odb History: yes  

Total pore fluid volume flux associated with the section.