Elements tested
- GK2D2
- GK2D2N
- GKPS4
- GKPS4N
- GKPS6
- GKPS6N
- GKAX2
- GKAX2N
- GKAX4
- GKAX4N
- GKAX6
- GKAX6N
- GKPE4
- GKPE6
- GK3D2
- GK3D2N
- GK3D4L
- GK3D4LN
- GK3D8
- GK3D8N
- GK3D6
- GK3D6N
- GK3D18
- GK3D12M
- GK3D18N
- GK3D12MN
ProductsAbaqus/Design Elements tested
Features testedThis section includes a general set of simple tests to verify the design sensitivity analysis (DSA) technique for gasket elements. Geometrically nonlinear tests are done for both total and incremental DSA formulations. Problem descriptionAll problems are static problems with gaskets sandwiched between continuum elements. The design parameters chosen govern the gasket section properties. Results and discussionThe results are verified by comparing them with the results from the overall finite difference method. Input files
|