Elements tested
T3D2
ProductsAbaqus/Standard Elements testedT3D2 Features testedDamping of substructures. Problem descriptionThe model consists of two substructures, each generated from truss elements of type T3D2. The model is oriented along the x-axis and is constrained at one end in all degrees of freedom. It is free to move only in the x-direction at its other end. In each case the truss is displaced by 25.4 mm (1 in) at its free end in an initial static step. It is then released in the direct-integration implicit dynamic (or modal dynamic) step, and the displacement response history is saved on a file for postprocessing. Results and discussionThe results from the substructure analysis exactly match the results that are obtained when substructures are not used. Input files
|