Creating an Piping ISO BOM Table Template

You can create a BOM table template by editing the report attributes, the NLS attributes, and the table layout.

See Also
About Fluidic System Bill of Materials Native Report
  1. From the Smart Template Administration section of the action bar, click Table Template .
  2. In the Table Template Definition panel, select Piping ISO BOM from the Report Name list.
  3. In the tree, double-click an attribute to modify it.

    Configure the report attributes, NLS attributes, and table layout.

    For example:

    • Edit the value of attribute BOMPartDescriptionMode to 1 (This will use the V_Description attribute for grouping check).
    • Edit the value of attribute BOMLengthUnits to mm.
    • Edit the value of attribute BOMLengthDigits to 0.
    • Edit the value of attribute BOMShowUnits to true (This will display the units in the report).
    • Edit the NLS attribute HeaderBlock_position_number to Item No.
    • Edit the size of 1st column to 10 mm.
    • Edit the row size attribute of HeaderBlock Element Class to fixed value 15 mm.
    • Edit the EKL Rule Piping_Pipe_Description to compute a custom description for Pipes.

  4. Rename the table template to Piping ISO BOM.

    Note: You must rename the table template, not the view contained in it.

  5. Save the drawing template representation.
  6. Open the catalog containing the table template chapter.
  7. In the tree, right-click the table template chapter and select Insert > Item: Feature, and select the newly created table template.

    This template can later be used by the user to create a table.