From the Smart Template Administration section of the action bar,
click Table Template
.
-
In the Table Template Definition panel, select Piping
ISO BOM from the Report Name list.
-
In the tree, double-click an attribute to modify it.
Configure the report attributes, NLS attributes, and table layout.
For example:
- Edit the value of attribute BOMPartDescriptionMode to 1 (This will use the
V_Description attribute for grouping check).
- Edit the value of attribute BOMLengthUnits to mm.
- Edit the value of attribute BOMLengthDigits to 0.
- Edit the value of attribute BOMShowUnits to true (This will display the units in
the report).
- Edit the NLS attribute HeaderBlock_position_number to Item No.
- Edit the size of 1st column to 10 mm.
- Edit the row size attribute of HeaderBlock Element Class to fixed value 15
mm.
- Edit the EKL Rule Piping_Pipe_Description to compute a custom description for
Pipes.
-
Rename the table template to Piping ISO BOM.
Note:
You must rename the table template, not the view contained in it.
-
Save the drawing template representation.
-
Open the catalog containing the table template chapter.
-
In the tree, right-click the table template chapter and select Insert >
Item: Feature, and select the newly created table template.

This template can
later be used by the user to create a table.
|