From the Applications section of the action bar, click CST
and drop it on the process diagram.
-
Double-click CST
.
-
From the CST Editor that appears, select the
Post-Update tab.
-
From the tree that
Optimization
Process Composer
displays in the
CST Editor, select the object containing the
3DEXPERIENCE
parameters.
-
Use the
Filters to reduce the number of items that
appear in the table. For example, you can choose to display only
3DEXPERIENCE
parameters or only the parameters that contain a particular text string in
their name.
You can also select a node in the tree to view the 3DEXPERIENCE parameters associated with that node. Use the Find
field above the tree to quickly locate the item in the tree. Drag the bar to the
right of the tree to expand or contract it as needed.
Note:
To start a search using the Find box, click or . Do not press Enter because
this will close the adapter window.
-
To map a
3DEXPERIENCE
parameter to an activity parameter with the same name, do the following:
-
Click in the
Select column for each parameter that you
want to add.
Optimization
Process Composer
creates the parameter with the same name and the same mode and type.
Note:
The mapping process maintains the value of Knowledgeware and PLM parameters in the user's
display units. For example, a Knowledgeware parameter representing a length
of 200mm, but with display units of meters, will be treated as a value of
0.2 by the activity parameter in the simulation process. Optimization
Process Composer does not support unit conversion. To reflect the change in display units
in the activity parameter's value, you must recreate the mapping by clearing
it, closing and reopening the CST Editor, and
selecting the mapping again.
-
To map a
3DEXPERIENCE
parameter to an existing activity parameter, do the following:
-
Select the
Activity Parameter column.
-
From the list, select the existing activity parameter to which
you want to map.
-
Click
OK.
-
To map a
3DEXPERIENCE
parameter to a new activity parameter, do the following:
-
Select the
Activity Parameter column.
-
Select
Create new.
The
Create New panel appears.
-
Enter the parameter name and value, and click
OK.
Optimization
Process Composer
creates the activity parameter and maps the
3DEXPERIENCE
parameter to the activity parameter.
- Optional:
Click
Select all or
Deselect all to add or clear parameters.
-
Click
Show selected to view the selected parameters.
-
Click
Validate to confirm that the selected
parameters exist and have valid units.
If a parameter is valid,
Optimization
Process Composer
reads its value from the
3DEXPERIENCE platform
and displays the value.
-
Click
Ok to save your changes and to close the
CST Editor.
|