| Define Thermal Conduction Contact Properties
      
          From the Interactions section of the action bar,
            click Contact Property
             .Optional:  
  Enter a descriptive 
	 Name. 
   
          Expand the Thermal Conduction Property section to access more
            options.
          
            
              Select Specify thermal conduction options.
            
              Select Use clearance-dependent data.
              The options in the Clearance tab become
                active.
              Select Use pressure-dependent data.
              The options in the Pressure tab become
                active.
              Optional: Select Use temperature-dependent
                  data, and enter values for Temperature in the
                table.
            
              Specify the Number of field variables, and enter values
                for those field variables in the table.
            
              In the table, enter values for Conductance,
                  Separation, and Pressure, as
                applicable.
            
          Click OK.
        
 
 Define Radiation Contact Properties
      
          From the Interactions section of the action bar,
            click Contact Property
             .Optional:  
  Enter a descriptive 
	 Name. 
   
          Expand the Radiation section to access more options.
          
            
              Select Specify radiation options.
            
              Enter a value as the Emissivity of main surface.
            
              Enter a value as the Emissivity of secondary
                surface.
            
              In the table, enter values for View Factor and
                  Clearance.
            
          Click OK.
        
 
 Define Electrical Conduction Contact Properties
      
          From the Interactions section of the action bar,
            click Contact Property
             .Optional:  
  Enter a descriptive 
	 Name. 
   
          Expand the Electrical Conduction Property section.
          
            
              Select Specify electrical conduction options.
            
              Select Use clearance-dependent data.
              The options in the Clearance tab become
                active.
              Select Use pressure-dependent data.
              The options in the Pressure tab become
                active.
              Optional: Select Use temperature-dependent
                  data, and enter values for Temperature in the
                table.
            
              Specify the Number of field variables, and enter values
                for those field variables in the table.
            
              In the table, enter values for Conductance,
                  Separation, and Pressure, as
                applicable.
            
          Click OK.
        
 |