From the Procedures section of the action bar, click Weld Defaults.
From the Structural stress type options, select one of
the following:
Option
Description
Normal
Structural stress normal to the weld lines.
Shear
Structural stress parallel to the weld lines.
Worst of normal/shear
Worse fatigue life computed from the normal and shear structural stress histories.
Multiaxial
Advanced multiaxial weld fatigue: Wang & Brown-based multiaxial cycle counter with
blending of normal and shear S-N master curves
From the Structural stress source options, select one of
the following:
Option
Description
Basic nodal force
Standard Battelle structural stress method. This method requires the creation of very
highly structured meshes on the crack surfaces.
Enhanced nodal force
Enhanced nodal force structural stress method. This method requires accurate modeling
of the crack surfaces but the mesh over that surface can be
unstructured.
From the l(r) function options, select one of the
following:
Option
Description
Displacement control
"Structural Joints / Displacement Control" method for defining the function of the
bending ratio, .
Load control
"Small Details / Load Control" method for defining the function of the bending ratio, .
From
the Mean stress correction options, specify one of the
following models to describe the default mean stress correction method for weld
fillet sets and weld line sets:
Option
Description
None
No mean stress correction.
User file
Performs mean stress correction based on user-specified data in a file in the
database.
The material used for the welds must have ultimate tensile
strength defined.
ASME Tensile
ASME Tensile method.
The material used for the welds must have monotonic yield
stress defined.
Modified Goodman (compressive only)
Modified Goodman method, suitable for brittle materials and welds.
The material
used for the welds must have ultimate tensile strength defined.
Battelle - Low Residual
Battelle - Low Residual method
Battelle - Compressive Residual
Battelle - Compressive Residual method
Set Toe failures to On to analyze
toe failure modes.
Set Throat failures to On to
analyze throat failure modes.
From the Throat failure sense options, specify how you
want the app to analyze throat failures:
Option
Description
From root or surface
Analyzes throat failures from the root to the surface line and vice
versa.
From root
Analyzes throat failures from the root to the surface line
only.
From surface
Analyzes throat failures from the surface line to the root
only.
Set Fusion failures to On to
analyze fusion failure modes.
From the Fusion failure sense options, specify how you
want the app to analyze fusion failures:
Option
Description
From root or surface
Analyzes fusion failures from the root to the surface line and vice
versa.
From root
Analyzes fusion failures from the root to the surface line
only.
From surface
Analyzes fusion failures from the surface line to the root
only.
Set Root failures to On to detect
root-through-plate failure modes automatically.
Specify the Number of smoothing iterations you want to
perform smoothing on the stress with respect to distance along the weld
lines.
By default, the app performs no smoothing iterations, but you can specify up
to 10.
Specify the Weld line split angle, which determines how
long weld lines with kinks in them are split into separate segments.
Specify the Failure plane tolerance, a tolerance in
degrees for the angle between the assumed failure plane normal and that of a
candidate element face.
Specify the Blunt root threshold, which controls the
handling of the weld root lines where there is a small gap in the model between
the base plate and the back of the weld line set.
For advanced multiaxial weld fatigue, set Shear to normal nonlinear
mapping to On to apply shear-to-normal
nonlinear mapping for multiaxial weld failure simulations.
For advanced multiaxial weld fatigue, specify the Normal-shear
covariance threshold, a proportionality threshold that relates
to the covariance between the normal and shear stress over the history.
For advanced multiaxial weld fatigue, select either of the following from the
Modified Wang and Brown list:
Option
Description
On
Uses the modified Wang and Brown criterion to start the reversal
scan.
Off
Uses the classical Wang and Brown criterion to start the reversal
scan.