You can create flanged holes by
specifying punch geometrical parameters.
Before you begin: Create a wall.
From the
Refine section of the
action bar,
click
Flanged Hole
.
Select the surface.
A grid appears to help you position the flanged hole.
From the
Definition list, select the diameter type.
Specify whether the flanged hole should be created with or without
a cone.
If you clear
With cone:
The height being
automatically computed.
The radius value for
the flanged hole external curvature must be specified.
Specify whether the flanged hole you be created with or without a
burring tap.
You can use design tables to define a burring tap. It is only
available if
With cone is selected.
Notes:
If you select
With tap:
The
Radius box is disabled, the radius being
automatically computed.
The
Flat diameter box is disabled and its
value is equal to
Diameter D or
Diameter d depending on the flanged hole
type. The diameter value should be similar in both folded and flat views.
The support diameter
is equal to the minor diameter or the major diameter value depending on the
flanged hole type.
The support height
is equal to height H.
Warning:
If the burring tap is created on non-planar
surfaces, you cannot generate an unfolded view in a drawing.
To specify the burring tap, define the thread type and parameters:
If you select
Metric Thick Pitch
or
Metric Thin Pitch:
A
Thread Description
box lists all available descriptions that use ISO
standards.
The
Pitch value depends on the selected
description. The path for the standard files is
win_b64\resources\standard\thread\Metric_Thick_Pitch.xml
or
win_b64\resources\standard\thread\Metric_Thin_Pitch.xml.
Note:
The thread diameter should be greater than the support
diameter.
Define the following parameters:
Option
Description
Height
Total height
Use the icon next to the box to specify the
reference from which the height is defined: or .
Radius
Radius for the external curvature
You can click
Sketch
to edit the positioning sketch.
Angle
Angle
This option is unavailable with the
Two diameters or
Punch & die parameters, as the angle
is automatically computed in these cases.
Major diameter
Major diameter
This option is unavailable if you select
Minor diameter, as the major diameter is
automatically computed.
Minor diameter
Minor diameter
This option is unavailable if you select
Major diameter, as the minor diameter is
automatically computed.
Choose the flat pattern diameter:
Option
Description
K-factor
Uses the K-factor to compute the diameter.
Flat diameter
Manually defines a diameter value.
Important:
The flat pattern diameter should not exceed the
flanged hole external contour.
To create a flanged hole without a fillet, enter clear
Use fillet.