About the Weight Attributes Table

The weight attributes table appears when declaring or computing weight.

This page discusses:

The weight attributes available in the table differ depending on the type of element selected (part, assembly) and on the action you are performing (declaring or computing weight).

The table below shows the attributes displayed when computing weight:

#AttributeValue
1Weight [Margin]0.002kg [0.002kg..0.003kg]
2CoG along X1.684e-008mm
3CoG along Y-2.713e-008mm
4CoG along Z-6.478e-009mm
5Volume3.176e-007m3
6Moment Ixx / G2.036e-007kgxm2
7Moment Iyy / G1.093e-007kgxm2
8Moment Izz / G1.093e-007kgxm2
9Product of Inertia Ixx / G0kgxm2
10Product of Inertia Ixz / G0kgxm2
11Product of Inertia Iyz / G0kgxm2
12Mean Density7860kg_m3
13Include in Weight SynthesisYes
14Comment

The table below shows the attributes displayed when retrieving weight:

#AttributeValue
1Weight [Statistical Margin]2.456kg [2.419kg..2.949kg]
2CoG along X434.959mm
3CoG along Y1.005mm
4CoG along Z-5.008mm
5Volume6.863e-004m3
6Weight maturity82%

To get more information on the kind of weight applied to a part, position the pointer over an attribute in the table.

To edit a value, select the corresponding cell, and either click the value or press F2. Then, type the value and press Enter.

Working with Declared or Computed Weights

The table below provides information about the icons available with the table when working with declared or computed weights:

IconAction
Switches to a floating view of the table with the tree displayed.
Switches back to the table-only view.
Closes the table and exits weight definition for the current element.
Switches to the tree view.
Switches back to the weight definition view.


Removes the previously declared or computed weight from the system.

Working with Computed Weights Only

The table below provides information about the icons available with the table only when working with computed weights:

IconAction


Launches a heavy update of weight values.

Provides the capability to update the permanently stored weight results for child products, depending on the associated geometry. This consequently updates the temporary weight results for parent assembly nodes.



Launches a light update of weight values.

Provides the capability to update the temporary weight results for assembly nodes (for instance, if filters are modified, or if a child node is removed from the assembly node).

Working with Declared Weights Only

The table below provides information about the icons available with the table when working with declared weights only:

IconAction
Computes inertia values when declaring the weight of a part or product.


Switches the reference axis system, from that of the root element (x, y, z) to the axis system of the selected element (0, 0, 0).