3DHvac_Part_Compatibility

This check verifies whether the part ports and the ports that they are connected to are compatible, based on the Compatibility Rule table. If not, the check fails.

This page discusses:

Context

When you place parts and create routes, the parts you choose must be compatible with one another and with the route. This check ensures that those parts are compatible.

Note: This check also fails if:
  • No specification is defined on the part.
  • No Compatibility Rule table exists in the specification.
  • The Compatibility Rule table does not return any values for the part ports.

For more information about the table, see HVAC Design Administration Guide: Data Setup: HVAC Resource Files: Resource Files - Common Tables: Compatibility Rule.

Check Information

Check Details Description
Applicable to: HVAC_Part_Occurrence
Automatic Solution:
Check Parameters: IsToUseAutoPartTable: Boolean type.

Specifies whether to use the Automatic Part table for the check. When set to TRUE, the check fails if the Automatic Part table is missing.

Note: By default, the value is set to TRUE.