Electrical Branch Geometry
The following table describes the weight computation for an electrical branch geometry.
Engineering Property | Formula | Legend |
---|---|---|
Mass | = Mass of electrical branch geometry = 1...n = Number of protections = Linear density of protection (kg/m) = Length of protection | |
Center of Gravity (CoG) | = Center of gravity of electrical branch geometry = 1...n = Number of protections = Center of gravity of protection = Mass of protection | |
Volume | = Volume of electrical branch geometry =1...n = Number of protections = Outer diameter of protection = Inner diameter of protection = Length of protection | |
Area | = Area of electrical branch geometry = 1...n = Number of protections = Outer diameter of protection = Inner diameter of protection = Length of protection | |
Moment of Inertia | = Moment of inertia of electrical branch geometry = Moment of inertia of protection = 1...n = Number of protections = Axial component of center of gravity of protection = Mass of protection |