Locate Line Fastener Seeding Issues
-
From the Connections section of the action bar,
click Connection Manager
.
-
In the Connection Manager, click the filter icon
in the Type column header.
- Uncheck all types except Line Fastener.
-
Click
to show the additional columns, and locate the Seeding column.
-
From the context menu, select Seeding resolution on all line fasteners.
The icon
displays in the Seeding column for any line fasteners that have compatibility seeding issues with weld curve projections.