Insulation Part

This section describes the Insulation Part table and how you can customize it.

This page discusses:

Overview

This section provides a brief overview of the Insulation Part Definition table.

The Insulation Part table allows selection of insulation for pipes.

In Data Setup, this table should be assigned to the Insulation Part item in the resource table of Piping/Tubing Discipline Resources with a Specification criteria.

Rule Customization

This section describes the customization options of the Insulation Part table.

A typical Insulation Part table is shown below:

V_NominalSize(string)MinTemperature(Fdeg)MaxTemperature(Fdeg)V_InsulationType(string)V_InsulationThickness(in)
2in50100Thermal0.0625
4in50100Thermal0.0625
10in50100Thermal0.125
12in50100Thermal0.1875
14in50100Thermal0.1875
20in50100Thermal0.1875
22in50100Thermal0.1875
32in50100Thermal0.25
38in50100Thermal0.25
40in50100Thermal0.25
46in50100Thermal0.25
48in50100Thermal0.25

To customize the table, enter a line in the spreadsheet for each nominal size and temperature range.

ParameterTypeImportanceDescription
V_PipeInsulationSpecStringDeprecatedProvides information for selection of the correct insulation. This column is used only if criteria value is <AnyValue>.
V_NominalSizeStringRequiredUsed for filtering
V_MinTemperatureTemperatureRequiredUsed for filtering
V_MaxTemperatureTemperatureRequiredUsed for filtering
V_InsulationTypeStringRequiredProvides information for selection of the correct insulation.
V_InsulationThicknessLengthRequiredThe thickness for the nominal size and temperature range
V_LinearWeightLengthOptionalLinear weights of insulation (0 if not set)

Sample Resource File

This section explains where to find the sample resource file.

The default location of XXX_XXX.InsulationReferenceDefinition.xls is

..\startup\EquipmentAndSystems\Piping\InsulationSpecification.

Note: The app optional content is not automatically installed along with the code. Contact your administrator if you must install the files you need. For more information, see Install Optional Content. You can also see Installation and Setup:Install: 3DEXPERIENCE Platform: Installing 3DEXPERIENCE Platform Services for the First Time: Installing Services One-by-One: Native Apps: Installing Native Apps: Installing a Native App.

Where Used

Used in this appWhenIs seen as
Piping & Tubing 3D DesignInsulating pipesTable Browser dialog box
Functional & Logical DesignCreating a Line IDPipe Insulation Specification list in Properties dialog box, Piping tab.