Insulation Specification
The insulation specification can be associated to an Insulation Part table. It can be defined for a piping/tubing logical object.
While applying the insulation, the insulation specification is retrieved from the piping/tubing line logical object.
You can check the insulation specification for a piping/tubing line logical object using the Edit > Properties command.
Filtration
When you create a Line ID, you can specify the Operating Temperature in the Properties dialog box. Then, when you use the Insulation option, only insulations with the required Nominal Size and the Operating Temperature value between the minimum and the maximum temperature appear in the Insulation Definition dialog box.