ProductsAbaqus/StandardAbaqus/Explicit
TypeModel data
LevelPartPart instanceAssembly
Required parameters
- CONSTRAINT NAME
-
Set this parameter equal to a label that will be used to refer to this constraint.
Optional parameters
- INFLUENCE DISTANCE
-
Set this parameter equal to the perpendicular distance from the edge-based surface within which all nodes or element facets on the solid surface (depending on the solid surface type) must lie to be included in the coupling constraint. The default value is half the thickness of the shell that was used to define the edge-based surface.
- POSITION TOLERANCE
-
Set this parameter equal to the distance within which nodes on the edge-based surface must lie from the solid surface to be included in the coupling definition. The default tolerance is 5% of the length of a typical facet on the shell edge.
Data lines to define the surfaces forming the coupling definitions
- First line
The edge-based surface name.
The solid surface name.
Repeat this data line as often as necessary to define all the surfaces forming the coupling definition. Each data line defines a pair of surfaces that will be coupled.