Static | No | No | No | No | 1:1 | Static Perturbation | No | No | No | No | One structural sequence with one static perturbation step is created. |
Static | No | No | Yes | No | 1:1 | Static Perturbation | No | No | No | Yes | Static perturbation step containing load case in a structural sequence. |
Static | Yes | No | No | No | 1:1 | Static Perturbation | No | Yes | Yes | No | Static perturbation step in a structural sequence. |
Static | Yes | No | No | Yes | 1:1 | Static Perturbation | No | Yes | Yes | No | Static perturbation step in a structural sequence. Bolt load is present in corresponding step along with other restraints and service loads. Bolt restraint will not be present. |
Static | No | Yes | No | No | 1:1 | Static | No | No | Yes | No | Static step in a structural sequence. Contact connection property migrates to contact pair with frictional contact interaction property. |
Static | No | Yes | No | Yes | 1:2 | Static | No | No | Yes | No | Two static steps in a structural sequence. The first step contains restraints and bolt loads. The second step contains service load and bolt restraint. Contact connection property migrates to contact pair with frictional contact interaction property. |
Static | Yes | No | Yes | No | n:1 | Static Perturbation | No | Yes | Yes | No | One static perturbation step for each load case in a separate structural sequence with LCP on. Contact connection property migrates to contact pair with frictionless contact interaction property. |
Static | Yes | No | Yes | Yes | n:1 | Static Perturbation | No | Yes | Yes | No | One static perturbation step for each load case in a separate structural sequence with LCP on. Contact connection property migrates to contact pair with frictionless contact interaction property. Bolt load is present in corresponding step along with other restaints and service loads. Bolt restraint will not be present. |
Static | No | Yes | Yes | No | n:1 | Static | No | No | Yes | No | One static step for each load case in a separate structural sequence. Contact connection property migrates to contact pair with frictional contact interaction property. |
Static | No | Yes | Yes | Yes | n:2 | Static | No | No | Yes | No | Two static steps for each load case in a separate structural sequence. The first step contains restraints and bolt loads. The second step contains service load and bolt restraint. Contact connection property migrates to contact pair with frictional contact interaction property. |
Non-preloaded frequency; no reference to static case | No | No | No | No | 1:1 | Frequency | No | No | No | No | Frequency step in a separate structural sequence. |
Non-preloaded frequency; no reference to static case | Yes | Yes | No | Yes | n/a | n/a | n/a | n/a | n/a | n/a | This frequency case is not valid and does not migrate. A warning is generated. |
Non-preloaded frequency; reference static case boundary conditions | No | No | No | No | 2:1 | One sequence with one static perturbation step; one sequence with one frequency step | No | No | No | No | Frequency step in a separate structural sequence containing the restraints from the static case. Static case is mapped to one of the combinations described above.
|
Non-preloaded frequency; reference static case boundary conditions | Yes | Yes | No | Yes | 1:1 | One sequence with one static step or static perturbation step | No | Yes/No | Yes | Yes/No | This frequency case is not valid and does not migrate. A warning is generated. |
Preloaded frequency (frequency case pointing at a static case) | No | No | No | No | 2:1 | One sequence with one static perturbation step; one sequence with one static step followed by one frequency step | Yes (in static step) | No | No | No | The static case is migrated with one of the combinations from rows 1-10 above. The frequency case is migrated to one structural sequence with one static step (containing all restraints and loads) followed by one frequency step. |
Preloaded frequency (frequency case pointing at a static case) | Yes | Yes | No | Yes | 1:1 | One sequence with one static step or static perturbation step | No | Yes/No | Yes | Yes/No | The static case is migrated with one of the combinations from rows 1-10 above. The frequency case is not valid and does not migrate. A warning is generated. |
Buckle (buckle case pointing to a static case with loads) | No | No | No | No | 2:1 | One sequence with one static perturbation step; one sequence with one buckle step | No | Yes/No | No | No | The static case is migrated with one of the combinations from rows 1-10 above. The buckle case is migrated to a buckle step in a separate sequence containing the loads and restraints from the static case. |
Buckle (buckle case pointing to a static case with loads) | Yes | Yes | No | Yes | 1:1 | One sequence with one static step or static perturbation step | No | Yes/No | Yes | Yes/No | The static case is migrated with one of the combinations from rows 1-10 above. The buckle case is not valid and does not migrate. A warning is generated. |
Harmonic case (is always referred to preloaded frequency case) | No | No | No | No | 1:1 | One sequence with one frequency step and one harmonic response step | n/a | n/a | n/a | n/a | Frequency case is migrated to a frequency step in one sequence. The harmonic case is migrated to a harmonic response step in the same corresponding sequence of referred frequency case followed by frequency step. |