From the Conductor Routing Assistant panel, click
Generate conductor routing report
.
An .xls file is generated. It contains two worksheets :
Conductors and Segments.
- Select the Conductors worksheet to display information about the conductors and their route.
The following information is available: - Identifier: identifies the corresponding row for a conductor or a conductor group in the sheet.
- Name: corresponds to the name of a conductor or conductor group.
- Route Status: status can be "Routed", "Not routed", or "Broken".
- From end and To end: indicates each end of a conductor.
- Electrical System: indicates the electrical physical system to which a conductor or conductor group belongs.
- Separation Code: indicates the separation code of a conductor.
- External diameter: indicates the external diameter of a conductor.
- Bend radius: indicates the bend radius of a conductor.
- Route segments: indicates the segments used in a conductor route.
Note:
Information about segments being fully or partially used is not provided in the report.
If the Compute alternate path based on 'EWR_ValidateSegmentInConductorRoute'
result option is selected, failed routes are also displayed. For more information, see
Conductor Routing. - Route segments length: accumulates the lengths of the segments used in a conductor route.
If the Compute alternate path based on 'EWR_ValidateSegmentInConductorRoute'
result option is selected, routed segments lengths for failed routes are also displayed. For more information, see
Conductor Routing. - Comment on route's SUCCESS/FAILURE: provides feedback on a routing outcome.
- Select the Segments worksheet to display information about segments.
The following information is available: - Use the filtering arrows to sort the provided information according to your needs.
|