From the
Formboard section of the
action bar,
click
Harness Flattening Parameters
, and define the parameters as follows:
-
In the
General
tab,
choose an
Active plane.
-
In the
Flattening Orientation
tab,
select
Device placed in the active plane.
For more information, see
Defining Harness Flattening Parameters.
- From the Formboard section of the action bar, click Extract
to duplicate your 3D harness content.For more information, see Extracting 3D Content.
-
From the Formboard section of the action bar, click Generate Layout
and, in the tree, select
an electrical geometry or an electrical physical system.
The whole geometry is highlighted and the
Generate Layout
dialog box appears.
- Optional:
Edit the Active plane and the
Angle Mode.
-
Click OK.
The entire content is
flattened on the active plane set previously.

By default, the flattened content is automatically reframed in the 3D area.
|